1) The panel CANNOT send notifications of
alarms and other events via voice message and
CANNOT be managed via telephone (DTMF)
(unless the GSM module is present, properly
programmed and operational).
!
2) The panel CANNOT send notifications of
alarms and other events via SMS and voice
message (unless there is a telephone line that
is present and properly programmed and oper-
ational) and CANNOT be managed via SMS.
!
3) The panel CANNOT send notifications of
alarms and other events to central stations and
CANNOT be managed via app (unless the IP
module is present and properly programmed
and operational).
!
4) The panel CANNOT send notifications of
alarms and other events via email, and to cen-
tral stations (unless GSM Module is present
and properly programmed and operational)
and cannot be managed via app.
Absoluta Plus and Absoluta 630
APPENDIX
81
MESSAGE
DESCRIPTION
System Comm. FTC
A communicator action (phone call, SMS, event broadcast) has not been success-
ful: call the installer. If the
PIN to default
fault is also present it means that the com-
municator is disabled because the
Master
user and Installer PINs are set to the
factory default: change the user PIN and call the installer.
WLS batt. low
Low Battery on one or more Wireless devices.
GSM Network
The GSM network cannot be found: wait for it to be reset. The SIM cannot be
found: call the installer. The GSM Module is under DoS
5
or Jamming
6
attack: call
the installer.
!
(2) (3)
GPRS Network
The GPRS network cannot be found: wait for it to be reset.
!
(3)
Main Receiv.Lost
The panel CANNOT transmit the events to the primary receiver. If the
MainRec
OFF-CMS
event is also present in the event log the central station has stopped re-
mote monitoring: call the installer and/or the central station.
2nd Receiv. Lost
The panel CANNOT transmit the events to the primary receiver. If the
2ndRec
OFF-CMS
event is also present in the event log the central station has stopped re-
mote monitoring: call the installer and/or the central station.
GSM FW mismatch
The GSM module firmware is incompatible with that of the panel and must be up-
dated: the GSM Module is disabled. Call the installer.
!
(2) (3)
IP FW mismatch
The IP module firmware is incompatible with that of the panel and must be up-
dated: the IP Module is disabled. Call the installer.
!
(4)
IP network
The IP Module is under DoS attack.
!
(4)
Generic Tamper
This message indicates that a wireless siren or a repeater opens or is removed
from the mounting surface: the log shows the tampered wireless sirens and repeat-
ers. Call the installer.
Fail Detect. nnn
This message signals that the enrolling process of the wireless detector nnn is not
complete, or that it is about 15 minutes that the wireless detector nnn do not com-
municate with the control panel. Call the installer.
Table 14
List of Faults:
1)
ONLY Grade 3 Control Panels;
2)
Depends on the zone fault label.
5
In computing, a denial-of-service attack (DoS attack)
is a cyber-attack where the perpetrator seeks to
make a machine or network resource unavailable to
its intended users by temporarily or indefinitely
disrupting services of a host connected to the
Internet.
6
Jamming is the act of deliberately disturbing radio
communications.