n
Disarm
This operation will Disarm all the Partitions common to
both the Digital Key and Reader in use.
1.
Hold the Key near the sensitive field of the Reader:
the
Green
light indicator will blink briefly to show
that the Partitions have been disarmed.
2.
Remove the Key when ALL the light indicators turn
OFF (Figure 5a).
+
During the programming phase, the Installer can
enable or not the Key to clear the Partition calls or
Control Panel calls when the system will be dis-
armed.
Ï
Keys used with the Absoluta 630 control panel al-
ways clear partition calls, and control panel calls.
Multi-PIN/Key Disarming
If the installer has pro-
grammed the multi PIN/Key disarming for a Partition,
you need to enter/use the number of programmed
PINs/Keys to disarm the Partition, before the pro-
grammed time expires, as follow (read also the same
paragraph on “Basic (Arming) Commands”.
1.
Enter a valid PIN then press
OFF
or hold a valid Key
near the sensitive field of the Reader: the
Green
light indicator blinks few seconds, then the
Red
light indicator turns ON indicating that you need to
use another PIN/Key to disarm the Partitions.
2.
Press
ESC
or wait for the display message
Enter
PIN
, before enter another valid PIN, then press
OFF
, or hold another valid Key near the sensitive
field of the Reader: the
Red
light indicator turns
OFF indicating the Partition disarming otherwise,
the
Green
light indicator blinks few seconds and
the
Red
light indicator stay ON, indicating that you
need another PIN/Key to disarm the Partitions.
3.
Press
ESC
or wait for the display message
Enter
PIN
, before enter another valid PIN, then press
OFF
, or hold another valid Key near the sensitive
field of the Reader: the
Red
light indicator turns
OFF indicating the Partition disarming.
n
Away Arm
This operation will Arm all the Partitions common to
both the Key and Reader in use.
1.
Hold the Key near the sensitive field of the Reader.
2.
Remove the Key when the
Red
indicator light turns
ON (Figure 5b).
+
If one of the programmed block conditions, for Arm-
ing, is active, you cannot Arm; the three light indi-
cators, first, flash one at a time and then begin to
flash all together.
+
To comply with EN50131 for the Reader, all 3 light
indicators will be switched off to “hide” the control
panel status, if the relative option is enabled.
Ï
Readers connected to the Absoluta 630 control
panel always show the status of the security sys-
tem.
n
Arm — A Mode
This operation will Arm and Disarm the Partitions in ac-
cordance with the
A Mode
Arming configuration (pro-
grammed by the Installer).
1.
Hold the Key near the sensitive field of the Reader:
the light indicators will light in turn (at 2 second in-
tervals), as shown in Figure 5.
2.
Remove the Key when the
Red
and
Amber
light in-
dicators are ON (Figure 5c): at this point the system
will Arm in
A Mode
.
+
When the reader’s
EN50131
option is disabled, the
amber
light indicator turns OFF when you remove
the key, if the key’s partitions does not match the
reader’s partitions.
Ï
The
amber
light indicator of readers connected to
the Absoluta 630 control panel, turns OFF when
you remove the key, if the key’s partitions does not
match the reader’s partitions.
For example:
if a Key is assigned to the
Partition n. 1
and a Reader is assigned to the
Partitions n. 1 and 2
,
the
Amber
light indicator turns ON when you hold the
Absoluta Plus and Absoluta 630
READER OPERATIONS
59
Figure 5
Disarm/Arm from ECLIPSE2 reader.