An audible signal will communicate the result of the
command:
Beep
, if action done;
Boop
, if action fails.
The appliance will turn ON/OFF immediately, and the
system will go back to step
1
.
n
Panel Arming/Disarming (
4
)
3
This operation is NOT possible with Grade 3 Con-
trol Panels.
This command will allow you to Arm and Disarm the
Panel in accordance with programming.
1.
Press
4
to access
Arming/Disarming
.
2.
Press:
Ø
0
to know the current status of the Partition Panel;
Ø
1
to
Arm
the Panel;
Ø
2
to
Disarm
the Panel;
Ø
either
3
,
4
,
5
or
6
to Arm the Panel, respectively
in
A
,
B
,
C
or
D
Mode.
+
Will be armed/disarmed ONLY the PIN’s Partitions.
The Control Panel status will be indicated by the follow-
ing messages:
<<Panel armed>>
(Messages 199+200), if the Panel is
armed;
<<Panel disarmed>>
(Messages 199+203), if the
panel is Disarmed;
<<Not ready, action will not be executed>>
(Mes-
sage 204), if there is any problem that inhibits the Panel
arming;
<<Not ready, press one to arm anyway>>
(Message
205), if there is any problem that inhibits the Panel arm-
ing, but it is possible to arm anyway.
In the last case, if
1
is pressed anyway to arm, the
messages
<<Panel armed>>
will follow (Message
199+200).
The Partitions will Arm/Disarm immediately, and the
system will go back to step
1
.
n
Arm/Disarm Single Partitions (
5
)
3
This operation is NOT possible with Grade 3 Con-
trol Panels.
This command will allow you to Arm/Disarm the Parti-
tions individually.
+
The Partition Identifier number
must always be 2
digits long
, if necessary enter the required 0 to fit.
1.
Press
5
to access
Arm/Disarm Single Partitions
.
2.
Enter the Identifier number of the Partition.
3.
Press:
Ø
1
to Arm the Partition in
Away
mode;
Ø
2
to
Disarm
the Partition;
Ø
3
to Arm the Partition in Stay mode;
Ø
4
to Arm the Partition in Stay with
Zero Delay
mode.
The partition status will be indicated by the following
messages:
<<Armed>>
(Message 200), if any action of arming
was successful;
<<Disarmed>>
(Message 201), if any action of disarm-
ing was successful;
<<Not ready, action will not be executed>>
(Mes-
sage 204), if any action of arming has been refused;
<<Not
ready,
press
one
to
arm
anyway>>
(Message 205), if the partition is not ready to arm, but it
is possible to arm anyway.
If
1
is pressed anyway to arm, the messages
<<Armed>>
will follow (Message 200).
The Partition will Arm/Disarm immediately, and the sys-
tem will go back to step
1
.
n
Enable/Disable Installer (
6
)
This command will allow you to Enable/Disable the In-
staller and Remote Service.
Press
1
to enable or
0
to disabled Installer.
Ø
If the installer has been enabled, the disabled com-
mand will be communicate with a beep;
Ø
if the installer has been disabled, the enabled com-
mand will be communicate with a beep.
n
Clear call queue (
7
)
If you are accessing your system via
Answering device
mode, press
7
to end the call.
If you are accessing your system via
Dialler
mode (after
receiving an Alarm message), press
7
to interrupt the
ongoing Alarm, and clear the call queue.
A
beep
will communicate the positive result of the re-
quired action.
n
Alarms Reset (
8
)
This command will allow you to clear Partition and/or
Control panel Alarms, and restore the system to
standby, depending on the Access level of the PIN used
via Telephone.
A
beep
will communicate the positive result of the re-
quired action.
n
Disable Current User PIN (
9
)
This command will allow you to Disable the entered
User PIN:
Ø
a
beep
will communicate the positive result of the re-
quired action.
Absoluta Plus and Absoluta 630 TELEPHONE OPERATIONS
67