3
On Grade 3 panels, access to the system via tele-
phone locks for 90 seconds if 3 consecutive invalid
PINs are entered.
The system will end the call automatically, if no valid
PIN is entered within 30 seconds (at default). This inter-
val can be customized from 1 to 254 seconds.
Entering Commands
Once your PIN has been recognized, you can enter the
Command Codes.
+
The system will end the call automatically, if no Key
is pressed within 2 minutes.
n
Cancel Command (
#
)
Press
#
to cancel the Command, and step back to the
Enter data phase.
Press
#
to delete incorrect digits: the system will emit
an audible feed back signal (2 beeps) to confirm that the
data has been deleted.
n
On Hook (
*
)
If you are accessing your system via “Answering de-
vice” mode, press
*
to end the call.
n
Remote Talk/Listen-in (
1
)
Ï
The Absoluta 630 control panel does not support
this function.
+
This command requires the
AS100
Audio Station.
Ø
Press
1
to start the remote
Listen-in
session, via
the Audio Station microphone.
Ø
Press
1
again to start the
One-way Talk
session,
via the Audio Station speaker.
+
If required, press
1
to switch from
One-way Talk
to
Listen-in
mode, and vice versa. The
One-way
Talk
and
Listen-in
modes cannot be active at the
same time.
Ø
Press
2
to start the
Two-way Talk / Listen-in
ses-
sion, via the Audio Station microphone and speaker.
This feature will allow you to listen in on the protected
premises and talk to whoever is present.
Two-way Talk / Listen-in
sessions can also be acti-
vated by the Personal Panic Button thus making this
feature extremely useful in emergency situations in-
volving the elderly or disabled.
+
If you press
1
during the
Two-way Talk
session,
the Control panel will switch to
Listen-in
mode.
+
If the sound quality of the
Two-way Talk
session is
poor, use the
One-way Talk
and
Listen-in
modes
(press
1
).
Ø
Press
4
to reduce the remote microphone audio
gain.
Ø
Press
5
to centre the remote microphone audio
gain.
Ø
Press
6
to increase the remote microphone audio
gain.
n
Zone/Partitions status (
2
)
This command will allow you to check on the status of
the Zones and of the Partitions.
+
The Zone and Partition Identifier number
must al-
ways be 3 digits long
. If necessary enter the re-
quired 0 to fit.
1.
Press
2
to check the Zone and Partitions status.
2.
Press
1
for Partition status or
2
for Zones status.
Partitions status
Press in sequence
1???
to
know the current status of the Partition
???
.
The Partition status will be indicated by the following
messages:
<<Armed>>
(Message 200), if the Partition is armed;
<<Armed stay>>
(Message 201), if the Partition is
armed in stay mode;
<<Armed stay with zero delay>>
(Message 202), if
the Partition is armed in stay mode with 0 delay;
<<Disarmed>>
(Message 203), if the Partition is disarmed.
boop
, If Partition Identifier entered is 0.
After the message, the system will go back to step
1
.
Zone status
Press in sequence
2???
to know the
current status of the Zone
???
.
The Zone status will be indicated by the following messages:
<<Active zone>>
(Messagge194), if the zone is active;
<<Tampered zone>>
(Message 195), if the zone is
Tampered;
<<Zone in fault>>
(Message 196), if the zone is fault;
<<Zone in alarm>>
(Message 197), if the zone in alarm;
<<Standby zone>>
(Message 198), if the zone is in standby;
boop
, if zone Identifier entered is 0.
After the message, the system will go back to step
1
.
n
Turn Reserved Outputs ON/OFF (
3
)
This command will allow you to turn ON/OFF the appli-
ances (Sprinkler system, Courtesy lights, etc.) con-
nected to the
Reserved
Outputs.
+
The Output Identifier number
must always be with
2 digits long
, if necessary enter the required 0 to fit.
1.
Press
3
to access
Output control
.
2.
Enter the Identifier number of the required Output.
3.
Press
1
to turn ON, or
0
to turn OFF the appliance
connected to the selected Output.
66