Key near the Reader; when you remove the Key from
the Reader,
only the Partitions n. 1
arms in
A Mode
and the
Amber
light indicator
turns OFF
.
n
Arm — B Mode
This operation will Arm and Disarm the Partitions in ac-
cordance with the
B Mode
Arming configuration (pro-
grammed by the Installer).
1.
Hold the Key near the sensitive field of the Reader:
the light indicators will light in turn (at 2 second in-
tervals), as shown in Figure 5.
2.
Remove the Key when the
Red
and
Green
light in-
dicators are ON (Figure 5d): at this point the system
will Arm in
B Mode
.
+
When the reader’s
EN50131
option is disabled, the
green
light indicator turns OFF when you remove
the key, if the key’s partitions does not match the
reader’s partitions.
Ï
The
green
light indicator of readers connected to
the Absoluta 630 control panel, turns OFF when
you remove the key, if the key’s partitions does not
match the reader’s partitions.
For example:
if a Key is assigned to the
Partition n. 1
and a Reader is assigned to the
Partitions n. 1 and 2
,
the
Green
light indicator turns ON when you hold the
Key near the Reader; when you remove the Key from
the Reader,
only the Partition n. 1
arms in
B Mode
and the
Green
light indicator
turns OFF
.
n
Disarm Patrol
Keys with the
Patrol
option can Disarm the system for
the programmed Patrol Time.
n
False Key
When an unrolled (false) Key is present at the Reader,
ALL the Reader’s light indicators fast blinking.
+
After 10 consecutive attempts with false keys, tam-
pering with the key reader is reported and no fur-
ther attempts can be made for 90 seconds (the key
reader is locked).
3
On Grade 3 panels, after 3 consecutive attempts
with false keys, tampering with the key reader is re-
ported and no further attempts can be made for 90
seconds (the key reader is locked).
n
Automation and Access Control
Ï
The Absoluta 630 control panel does not support
this function.
The installer can program the Key Readers and Keys to
perform automatic operations like opening gates and
access control.
+
These types of Key Readers and Keys CANNOT
perform arming and disarming operations.
1.
Hold the Key near the sensitive field of the Reader:
the green light will turn on.
2.
Move the Key away from the sensitive field of the
Reader: the green light will turn off.
60
Expandable Hybrid Control Panels