The display’s central part lists Partitions common to the
Keypad and to the PIN used to login and the Partition
status.
Ø
Disarmed
, if the Partition is disarmed;
Ø
Away
, if the Partition is armed in Away mode;
Ø
Stay
, if the Partition is armed in Stay mode;
Ø
No Delay
, if the Partition is armed in Stay mode,
without Entry and Exit Delay;
Ø
Al.
, if the Partition is in alarm status;
Ø
AI.M.
, if the alarm status has occurred in the past
(memory);
Ø
Byp.
, if a zone of the partition is bypassed;
Ø
T.
, if one Zone of the Partition is being tested.
+
If a zone is being tested, contact your installer for
more information.
1.
Press
or
to scroll the list, then press
to
view Arming Modes:
2.
Press the desired Arming Mode to change Partition
status:
The keypad goes to Standby when the operation se-
lected is over.
n
Zone Status
This option allows you to view Zone status and by-
pass/include Zones.
+
On Grade 2 panels, only Master Users can by-
pass/un-bypass zones.
On Grade 3 panels, only Super Users can by-
pass/un-bypass zones.
The display’s central part lists the Zones of Partitions
common to the Keypad and PIN used to access them.
The
Bypass
/
Resume
key is displayed for each zone (if
the
Bypassable
option is enabled for that zone) and
status, as shown in the following table.
Test
: the zone cannot cause alarms but its activi-
ties are memorised in the events log; this can
only be enabled/disabled by the installer and is to
check correct zone operations without causing
undesired alarms; contact the installer.
Bypassed
: the zone CANNOT cause alarms and
its activities are NOT memorised in the Events Log.
Inactive
: (Absoluta Plus only) the zone has not
shown any signs of activity for some time; it might
not operate regularly or its detector could be
masked; contact the installer.
Alarm
: the zone has detected an intruder.
Low Battery
: the wireless detector battery en-
rolled on the zone must be replaced as soon as
possible; contact the installer.
Fault
: detector connections with the zone are
short or interrupted; contact the installer.
Masked
: the detector connected to the zone is
faulty (masked, etc.); contact the installer.
Tamper
: the detector connected to the zone has
been tampered with (open, detached from wall,
etc.); contact the installer.
Lost
: the wireless detector enrolled on the zone
has not been communicating for some time; con-
tact the installer.
Standby
: the zone operates regularly.
+
If several statuses are present at the same time,
the icon for the status with highest priority is dis-
played.
30