Basic commands
You can control seven basic commands from standby
status by typing-in your PIN and pressing the respective
keys (refer to the following Table). Access to ALL com-
mands require entry a valid User PIN.
!
The Factory Default Master User PIN (0001 for
Grade 2 Control Panels and 00001 for Grade 3
Control Panels) must be changed for security
reasons (refer to “Change my PIN” in this
section).
Key sequence
(from standby status)
COMMAND
<PIN> OFF
Disarm
<PIN> ON
Arm
<PIN> A+ON
A Mode Arm
<PIN> B+ON
B Mode Arm
<PIN> C+ON
C Mode Arm
<PIN> D+ON
D Mode Arm
<PIN> ENTER
View Area status, if there are
no Troubles. From the View
Area
status
or
Trouble
screen, press
ENTER
, to ac-
cess the User menu.
+
Commands will affect
only
the Partitions common
to both the User PIN and Keypad concerned (com-
mon Partitions).
Invalid commands will be signaled by a buzz and the
following message:
May/26/10 13:54
Invalid PIN!
Invalid commands may be due to the User PIN Keypad
Partitions.
+
If you do not press a key within 30 seconds, the
keypad will revert automatically to standby status
except during the input of the PIN. If the input is not
completed the display keypad will show “WRONG
PIN”, after one minute.
The User can
ENTER
the following commands at the
Keypad.
n
Arming (<PIN> ON)
This command will Arm all the common Partitions of the
User PIN and the Keypad concerned.
If a Exit Delay is set, the keypad will signalize it on the
display and the buzzer will emit a series of beep.
When the control panel is armed, each time you press
ESC
, the temperature displays (see “Temperature dis-
play” on page 37) alternates with date and time
displays.
n
Disarming (
<
PIN
>
OFF)
This command will Disarm all the common Partitions of
the User PIN and the Keypad concerned.
Disarm under Duress (PIN with Duress option en-
abled)
. This command requires entry of a
Duress PIN
.
The Control panel will Disarm the Partitions and will
send the programmed Alarm calls but will not signal the
outgoing calls on the Keypad (usually signalled by a
over the
i
icon).
+
DURESS
PINs are for forced disarming (disarming
under threat). The Duress PIN will disarm the sys-
tem and activate the Digital Communicator— that
will call the Central Station, and dialler—that will
send recorded voice messages to the programmed
telephone numbers.
Disarm by Patrol PIN
If a Patrol PIN (PIN with Patrol
option enabled) is used to Disarm the Partitions; the
Control panel will rearm the Partitions automatically
when the programmed Patrol Time expires.
+
PATROL PINs are enabled for Global arming / dis-
arming. PATROL PINs can disarm partitions tem-
porarily. Partitions disarmed by a PATROL PIN will
be rearmed automatically when the programmed
Patrol time elapses.
Multi-PIN/Key Disarming
If the installer has pro-
grammed the multi PIN/Key disarming for a Partition,
you need to enter/use the number of programmed
PINs/Keys to disarm the Partition, before the pro-
grammed time expires, as follow (read also the same
paragraph on “Key operations”).
1.
Enter a valid PIN then press
OFF
or use a valid Key:
Required others
PINs or Keys
2.
Press ESC or wait for the display message
Enter
PIN
, before enter another valid PIN, then press
OFF
, or use another valid Key: the display shows the
following message if no other PIN/Key is required
PANEL
DISARMED
otherwise shows the following message
Required others
PINs or Keys
3.
Press
ESC
or wait for the display message
Enter
PIN
, before enter another valid PIN, then press
OFF
, or use another valid Key: the Partitions
disarm
PANEL
DISARMED
40
Expandable Hybrid Control Panels