Installation
Bennett HF H35 Instruction Manual
27
FINAL INSTALLATION CHECKLIST
The Final Installation
Checklist must be completed to ensure a successful and safe installation that meets Bennett’s Limited Warranty
requirements.
Completed √
Item
Procedure
☐
1
Verify that all hydrogen fittings are tight and not leaking.
☐
2
All hanging hardware must be checked for proper installation and no leaks.
☐
3
The units must be properly bolted to the island.
☐
4
Vent line must not contain vapor traps.
☐
5
Electrical field conduits must be properly potted per local, state, and national codes.
☐
6
Equipment must be installed in conjunction with an emergency power cutoff to remove all power from the
equipment in the case of an emergency. Test this system for proper operation.
☐
7
All grounds must be properly connected per the installation manual requirements as well as local, state, and
national codes.
☐
8
Use of properly sized neutral breaking circuit breakers for the units involved.
☐
9
All dispenser electrical power is wired to the same phase of electrical power.
☐
10
Use 2 wire shielded cable or 2 wires together for the card reader RS-485 communications circuit.
(Bennett highly suggests that these should be twisted at least 3 times per foot.)
☐
11
Use 3 wire shielded cable or 3 wires together for the Fuel RS-485 communications circuit.
(Bennett highly suggests that these should be twisted at least 3 times per foot.)
☐
12
Use 2 wire shielded cable or 2 wires together for the PLC RS-485 communications circuit.
(Bennett highly suggests that these should be twisted at least 3 times per foot.)
☐
13
New site wiring must be megger tested. Pull new wires in conduits in existing installations.
☐
14
Verify the correct brand panels, nozzles, and hoses are installed for each grade.
☐
15
Verify that all valves are in the proper position.
☐
16
Calibrate the meters. Refer to the
☐
17
Close and lock all dispenser covers, panels, and doors.
☐
18
Verify that standard bolts have replaced the eyebolts used for transporting the dispenser.
Summary of Contents for HIGH FLOW H35
Page 12: ...Product Introduction Bennett HF H35 Instruction Manual 8 DISPENSER IDENTIFICATION NUMBER DIN...
Page 84: ...Schematics Bennett HF H35 Instruction Manual 80 CHAPTER 8 SCHEMATICS...
Page 85: ...Schematics Bennett HF H35 Instruction Manual 81...
Page 86: ...Schematics Bennett HF H35 Instruction Manual 82...
Page 87: ...Schematics Bennett HF H35 Instruction Manual 83...
Page 88: ...Schematics Bennett HF H35 Instruction Manual 84...
Page 89: ...Schematics Bennett HF H35 Instruction Manual 85...
Page 90: ...Schematics Bennett HF H35 Instruction Manual 86...
Page 91: ...Schematics Bennett HF H35 Instruction Manual 87...
Page 92: ...Schematics Bennett HF H35 Instruction Manual 88...
Page 93: ...Schematics Bennett HF H35 Instruction Manual 89...
Page 94: ...Schematics Bennett HF H35 Instruction Manual 90...
Page 95: ...Schematics Bennett HF H35 Instruction Manual 91...
Page 96: ...Schematics Bennett HF H35 Instruction Manual 92...
Page 97: ...Schematics Bennett HF H35 Instruction Manual 93...
Page 98: ...Schematics Bennett HF H35 Instruction Manual 94...