Programming
Bennett HF H35 Instruction Manual
50
Address Ranges:
•
Current Loop is 0 through 3
•
Generic Loop is 0 through 99
•
RS485 is 0 through 99
1.
Press the number
2
and
2
, then the [
MODE]
button on the keypad. The
PPM display shows the dispenser in Menu Code 22. If the dispenser has
not been programmed since it came from the factory, the default
address appears in the main display.
2.
To change the setting use the numeric keypad to enter a new address.
This option will only accept the options listed above.
Note
: If an error is
made, press the correct number. The new number replaces the error.
3.
Press [
ENTER
] to save setting and to advance to the next option. If
programming is complete, press [
CANCEL]
button to exit this menu
option.
4.
Press the [
CANCEL
] button again to exit mode 22.
Figure 4.35
–
Dispenser Address
PROCEDURE
–
SETTING PLC ADDRESS (MODBUS SECONDARY ID)
This option is used to enter the PLC Modbus Secondary ID (if applicable). The PLC Modbus Secondary ID address range is 0 through
247. The default setting is set at 0.
PLC Address Range
: PLC Modbus Secondary ID is 0 through 247
PROGRAMMING PROCEDURE
1.
Press the number
2
and
2
, then the [
MODE]
button on the keypad. The
PPM display shows the dispenser in Menu Code 22. If the dispenser has
not been programmed since it came from the factory, the default
address appears in the main display.
2.
To change the setting, use the numeric keypad to enter a new address.
Note
: If an error is made, press the correct number. The new number
replaces the error.
3.
Press [
ENTER
] to save the new setting and to cycle to the next available
option. If programming is complete press, [
CANCEL
] to exit this menu
option.
4.
Press the [
CANCEL
] button again to exit mode 22.
Figure 4.36
–
PLC Modbus Secondary ID
PROCEDURE
–
SETTING PLC LOWEST ADDRESS
This option is used to enter the lowest PLC address sent by the PLC (if applicable). The dispenser needs to know the lowest address
sent by the PLC so the dispenser can verify the address and map the addresses to the data correctly. The lowest address could be
0 or 1. The default setting is set at 0. However, some PLCs have a lowest address of 1.
PROGRAMMING PROCEDURE
1.
Press the number
2
and
2
, then the [
MODE]
button on the keypad. The
PPM display shows the dispenser in Menu Code 22. If the dispenser has
not been programmed since it came from the factory, the default
address appears in the main display.
2.
To change the setting, use the numeric keypad to enter a new address.
Note
: If an error is made, press the correct number. The new number
replaces the error.
3.
Press [
ENTER
] to save the new setting and to cycle to the next option.
4.
If programming is complete press, [
CANCEL
] to exit this Menu Code.
Figure 4.37
–
PLC Lowest Address
Sale $
d i s p E N
Kilograms
A d r 0
C O d E
2 2
Sale $
P L C
Kilograms
A d r 0
C O d E
2 2
Sale $
P L C L O
Kilograms
A d R 0
C O d E
2 2
Summary of Contents for HIGH FLOW H35
Page 12: ...Product Introduction Bennett HF H35 Instruction Manual 8 DISPENSER IDENTIFICATION NUMBER DIN...
Page 84: ...Schematics Bennett HF H35 Instruction Manual 80 CHAPTER 8 SCHEMATICS...
Page 85: ...Schematics Bennett HF H35 Instruction Manual 81...
Page 86: ...Schematics Bennett HF H35 Instruction Manual 82...
Page 87: ...Schematics Bennett HF H35 Instruction Manual 83...
Page 88: ...Schematics Bennett HF H35 Instruction Manual 84...
Page 89: ...Schematics Bennett HF H35 Instruction Manual 85...
Page 90: ...Schematics Bennett HF H35 Instruction Manual 86...
Page 91: ...Schematics Bennett HF H35 Instruction Manual 87...
Page 92: ...Schematics Bennett HF H35 Instruction Manual 88...
Page 93: ...Schematics Bennett HF H35 Instruction Manual 89...
Page 94: ...Schematics Bennett HF H35 Instruction Manual 90...
Page 95: ...Schematics Bennett HF H35 Instruction Manual 91...
Page 96: ...Schematics Bennett HF H35 Instruction Manual 92...
Page 97: ...Schematics Bennett HF H35 Instruction Manual 93...
Page 98: ...Schematics Bennett HF H35 Instruction Manual 94...