Belarus-1025/1025.2/1025.3
Section K. Storage regulations
Section K
STORAGE REGULATIONS
If indoors premises are not
available, tractors may be stored on
outdoor special sites, with obligatory
preservation, sealing and components
dismounting, that require warehousing.
Put tractors in the inter-shift storage,
if their operation is interrupted for up to 10
days, short-term storage if duration of idle
interval is from ten days to two months,
and long-term storage if interruption of use
lasts for over two months. Start preparation
for short-term storage straight after works
completion, and for long-term storage – not
later than ten days after works termination.
Before putting to storage, check technical
state of the tractor. It must undergo
scheduled maintenance.
Technological maintenance when
preparing tractor for long-term storage
includes:
Cleaning and washing , dismounting
and preparing for storage tractor
components subject to storage in specially
equipped warehouses, sealing of openings
and cavities from ingress of moisture and
dust, tractor and its components’
preservation, putting tractor on supports
(plates).
After operation tractor is cleaned off
dust, mud, oil leaks, vegetation and other
remains. Components where water is not
allowed (generators, relays, etc.), are
protected with sheathes. After tractor is
cleaned and washed, it is blown off with
compressed air to remove moisture.
Damaged painting is restored by putting
varnish and paint coating or protective
grease.
Paint coating should be deposited
according to GOST 6572-91.
With long-term outdoor storage,
electrical equipment, components made of
rubber, polymer materials and textile (
hoses of hydraulic systems, etc, are
dismounted, prepared for storage and sent
to warehouse. Fastening parts of
dismounted tractor components are
reinstalled. Electrical equipment
(headlights, generator, starter, storage
batteries) are cleaned, blown with
compressed air, terminals are coated with
protective grease.
When putting tractor in long-term
storage, descale and wash diesel cooling
system, lubricate all tractor assemblies
according to the lubrication chart. Drain oil
and fill fresh oil with additives to the control
level in diesel casing, air purifier sump,
cases of gear box, rear and front axles,
wheel reduction gear, intermediate
supports, oil tank of the hydraulic system.
Run tractor in for 10-15 minutes. Drain
cooling fluid out of the cooling system, and
cabin cooling and air heating system. Drain
fuel out of the fuel system, rinse inside
tanks’ surfaces with inhibitor lubricants and
tightly close filling necks. Use preservation
mixture to preserve fuel system and diesel
cylinders. Put storage batteries in long-term
storage after conducting control-training
cycle in accordance with GOST 9590-76.
Exposed joints, threaded connections,
steering trapezoids, grooved surfaces of
PTO drive end and gimbal gears, extended
sections of cylinders’ and suspensions’
rods, mechanisms for adjusting wheels
span