Belarus 1025/1025.2/1025.3
Section I. Possible malfunctions
I15
Malfunction, symptom
Correction method
Too humid warm air is fed to cabin
Fluid leakage in heater radiator
Eliminate leakage or replace radiator.
Fluid leakage in system connections Tighten coupling clamps of heater
Pneumatic system
Slow build-up of pressure in the cylinder
Air leakage from pneumatic system:
•
nuts of pipelines, fittings, coupling
Find out leakage sites and eliminate them
•
clamps are poorly tighten or damaged by tightening couplings or replacing
damaged parts
•
rubber sealing of connecting head is
Replace damaged sealing
damaged
•
loose nut of connecting head sealing ring Tighten it
•
mud under connecting head valve
Clean it
•
contact of dust-protecting cover with
Eliminate it
valve rod of the connecting head
•
deformed valve parts, torn diaphragm, Check state of valve parts and, if necessary
loose cover fastening in the brake valve replace them, tighten fastening bolts.
- disturbed adjustment of valve drive
Make adjustment (see section
“Adjustments”).
•
disturbed operation of pressure controller Dismount it and send to workshop for
repair.
Air leakage via compressor valves
Dismount compressor head, clean valves
and seats off coke deposits
Replace damaged parts.
Hang up or wear of compressor piston
Dismount compressor head and cylinder
rings
clean rings off coke deposits and, if
necessary, replace them