Parameter Descriptions 7-17
MN765
Block Title Parameter (Number)
Selection (Value)
Parameter Name and Description
DRIVE
CONFIG
SPEED UNITS
(2101)
Preset Value: 1
Range: 0 - 1
Hz (0) Sets units to Frequency, Hz.
RPM (1) Sets units to RPM.
LANGUAGE SELECT
(2102)
Preset Value: 0
Range: 0 - 1
English (0) Sets English as displayed text.
Other (1)
Sets "OTHER", (Spanish, German, Italian, French, or Portuguese) English
and one language can be stored (Spanish, German, Italian, French and
Portuguese). Standard firmware allows English and Spanish. For other
languages, language tables must be loaded into the drive’s language flash
area.
FACTORY SETTINGS
(2103)
Preset Value: 0
Range: 0 - 1
No (0) No Action.
Yes (1) Restores factory settings for all parameters. (Overwrites all stored values for
all four parameter tables).
SECURITY
(2105)
Preset Value: 0
Range: 0 - 3
Off (0) Security not enabled.
Local (1) Security enabled for keypad only.
Network (2) Security enabled for Network only.
Total (3) Security enabled for both Keypad and Network.
Enables Security.
ACCESS TIMEOUT
(2106)
Preset Value: 5.0
Range: 1.0 - 600.0 seconds
If security is enabled and program mode is entered, the access code must be
correctly entered. After parameters are changed and program mode exited
this timer begins to timeout. If program mode is accessed after timeout, the
security code must be entered a second time.
ACCESS CODE
(2107)
Preset Value: 9999
Range: 0 - 9999
Sets security code for login required to access locked parameters.
ACTIVE PARAM TBL
(0052)
Preset Value: 0
Range: 0 - 3
T1 (0) Table 1 is used as active parameter set.
T2 (1) Table 2 is used as active parameter set.
T3 (2) Table 3 is used as active parameter set.
T4 (3) Table 4 is used as active parameter set.
Note: This parameter is not actually in the Level 2 Blocks. It is Parameter
0052 in the MONITOR block if using Workbench.
CLEAR FAULT LOG
(2108)
Preset Value: 0
Range: 0 - 1
No (0) No Action.
Yes (1) Deletes all fault log entries and trace values.
DEAD TIME COMP
(2109)
Only available or active in V/F
mode. Ignore this parameter for
Open/Closed Vector mode.
Preset Value: 100.0
Range: 0 to 100.0%
Compensates for voltage loss due to switching dead time at the PWM output.
Table 7-2 Level 2 Parameter Block Definitions Continued
Summary of Contents for VS1GV21-1B
Page 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Page 12: ...2 2 General Information MN765...
Page 16: ...3 4 Installing the Drive MN765...
Page 78: ...6 16 Using the Keypad MN765...
Page 132: ...9 14 Troubleshooting MN765...
Page 172: ...A 16 Technical Specifications MN765...
Page 200: ...E 2 Remote Keypad Mounting Template MN765...
Page 201: ...Remote Keypad Mounting Template E 3 MN765...