7-4 Parameter Descriptions
MN765
Block Title Parameter (Number)
Selection (Value)
Parameter Name and Description
KEYPAD
SETUP
(Continued)
DOWNLOAD SELECT
(1311)
Preset Value: 0
Range: 0 - 2
All (0) All parameters.
Motor (1) Motor parameters only.
Other (2) All parameters except Motor parameters.
Selects parameters to download (All, Motor or Other) with “Keypad to Params”
(P1312). See Appendix B for notation of which parameters are motor related.
KEYPAD TO PARAMS
(1312)
Preset Value: 0
Range: 0 - 1
No (0) No action.
Yes (1) Transfers the parameter settings stored in keypad memory to the control memory
(flash).
KEYPAD CONTRAST
(1313)
Preset Value: 50
Range: 0 - 100%
Sets LCD contrast: 0=dimmest, 100=brightest.
BACKLIGHT
(1314)
Preset Value: 1
Range: 0 - 1
Off (0) Sets the Keypad Display backlight OFF.
On (1) Sets the Keypad Display backlight ON.
LOC TORQUE MODE
(1315)
Closed/Open Vector Only
Preset Value: 0
Range: 0 - 1
Off (0) Disables local torque mode.
On (1) Enables local torque mode operation.
LOC TORQUE REF
(1316)
Closed/Open Vector Only
Preset Value: 0.00
Range: -100.00 to 100.00%
Local torque mode reference value.
INPUT
SETUP
OPERATING MODE
(1401)
Preset Value: 0
Range: 0 - 16
Keypad (0) Drive operates from keypad only.
Standard Run 2Wire (1) Drive operates from digital inputs and command source. Preset Speed 1 may also
be selected.
Standard Run 3Wire (2) Drive operates from digital inputs and command source. Preset Speed 1 may also
be selected.
15 Preset Speeds (3) Operation in 15 Preset Speeds 2 Wire Mode is controlled by digital inputs at J2.
Speeds set in parameters P1001 to P1015.
Fan & Pump 2Wire (4) Operation in Fan & Pump 2 Wire controlled by digital inputs at J2.
Fan & Pump 3Wire (5) Operation in Fan & Pump 3 Wire controlled by digital inputs at J2.
Process Control (6) The Process Control provides an auxiliary closed loop general purpose PID set
point control.
3Spd Ana 2Wire (7) Provides 2 Wire control and allows selection of 3 Preset Speeds.
3Spd Ana 3Wire (8) Provides 3 Wire control and allows selection of 3 Preset Speeds.
E-Pot 2Wire (9)
Electronic Potentiometer provides digital inputs for Speed Increase and Speed
Decrease. Also provides 2 digital inputs for selection of E-Pot or "Command
Source" (1402), Preset Speed 1, and Preset Speed 2.
E-Pot 3Wire (10)
Electronic Potentiometer provides digital inputs for Speed Increase and Speed
Decrease. Also provides a digital input for selection of E-Pot or “Command Source”
(1402).
Network (11) Provides Bipolar speed or torque control.
Profile Run (12) Provides a seven segment speed profile for cyclic operation or test cycle. See
Level 3, Profile Run Block.
Table 7-1 Level 1 Parameter Block Definitions Continued
Summary of Contents for VS1GV21-1B
Page 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Page 12: ...2 2 General Information MN765...
Page 16: ...3 4 Installing the Drive MN765...
Page 78: ...6 16 Using the Keypad MN765...
Page 132: ...9 14 Troubleshooting MN765...
Page 172: ...A 16 Technical Specifications MN765...
Page 200: ...E 2 Remote Keypad Mounting Template MN765...
Page 201: ...Remote Keypad Mounting Template E 3 MN765...