6-4 Using the Keypad
MN765
6.3 Menu Display
After power-up the display shows the Status screen. Press the Menu key to display menu options.
Action
Description
Display
Comments
Status Display
STATUS
STOP
LOCAL
DIAG
0.00r
MAIN
0.0V
0RPM
0.0A
0.0HZ
Press Menu/Esc
Displays top level menu options.
DIAG
BACK
STATUS
BASIC PARAMS
ADVANCED PROG
EVENT LOG
DIAGNOSTICS
Press or
to move cursor over
the desired selection the press
“Enter” to select and display the
selection.
6.4 Basic Params
From the Menu display screen, select Basic Params and press Enter.
Parameter Status
All programmable parameters are displayed with an “F” at the bottom center of the display. “F” means it is the factory
setting value. “C” means it is a custom value set by the user. “V” means the parameter value may be viewed but not
changed while the motor is operating. If the parameter is displayed with an “L”, the value is locked and may not be changed
until the security code is entered.
Action
Description
Display
Comments
Basic Params Display
Control type display. The
parameter number “1601” is given
at the bottom center of the
display. “F”1601 indicates it is at
the factory setting and has not
been changed.
BASIC
STATUS
F1601T1
BACK
CONTROL TYPE
V/F Control
MOTOR CONTROL
Press Enter to select the
parameter and press the
or
keys to change the preset value
to a different control type.
Press enter when finished to exit
and save the new value or F2 to
exit without saving.
Press
to go to the
next Basic Params
screen.
BASIC
STATUS
F2401T1
BACK
MOTOR RATED VOLT
240.0 V
MOTOR DATA
T1 indicates the Table Number or
the parameter list in use. Four
parameter tables are available,
T1, T2, T3 or T4
(See Level 2, Drive Config, Active
Param Table parameter P0052.)
Press
to go to the
next Basic Params
screen.
BASIC
STATUS
F2402T1
BACK
MOTOR RATED AMPS
9.6 A
MOTOR DATA
Press to go to the
next Basic Params
screen.
BASIC
STATUS
F2405T1
BACK
MOTOR MAG AMPS
3.1 A
Press to go to the
next Basic Params
screen.
BASIC
STATUS
F2403T1
BACK
MOTOR RATED SPD
1754 RPM
MOTOR DATA
MOTOR DATA
Press
to go to the
next Basic Params
screen.
BASIC
STATUS
F2416T1
BACK
MOTOR RATED HP
10.0 HP
MOTOR DATA
Summary of Contents for VS1GV21-1B
Page 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Page 12: ...2 2 General Information MN765...
Page 16: ...3 4 Installing the Drive MN765...
Page 78: ...6 16 Using the Keypad MN765...
Page 132: ...9 14 Troubleshooting MN765...
Page 172: ...A 16 Technical Specifications MN765...
Page 200: ...E 2 Remote Keypad Mounting Template MN765...
Page 201: ...Remote Keypad Mounting Template E 3 MN765...