12-2 Monitor and RTC Description
MN765
P#
Type
Name
Unit
Help
33
LINE VOLTAGE
V
Line Voltage. - Estimated drive input line-to-line RMS voltage
34
RATED A/V
V
Rated Amps/Volt. - Nominal drive current scaling set at the factory
35
MOTOR POLES
Motor Poles. - Calculated /entered number of motor poles
36
RUN TIMER
HR
Run Timer. - Accumulated drive run (non-idle) time in hours
37
ACTIVE ALARMS
Active Alarms. - Number of currently active /simultaneous alarms
38
ACT ALARM CODE
Active Alarm Code. - Currently active alarm code
39
ANA IN1
V
Analog Input 1. - Measured value of analog input #1 on terminal input
J1-2 and J1-1
40
ANA IN2
V
Analog Input 2. - Measured value of analog input #2 on terminal input
J1-4 and J1-5
41
ANA OUT1
V
Analog Output 1. - Estimated value of analog output #1 on terminal J1-6
42
ANA OUT2
V
Analog Output 2. - Estimated value of analog output #2 on terminal J1-7
43
OPTION1
Option 1. - Option board detected in option slot #1 (left slot)
44
OPTION2
Option 2. - Option board detected in option slot #2 (right slot)
45
FEEDBACK
Feedback. - Feedback board detected in motor feedback board slot
46
DATE AND TIME
Current Date and Time. - Real time clock current reading
47
DST STATUS
DST Status. - Daylight Saving Time status: 0=Not Active 1=Active
48
MOTOR OVERLOAD
REMAINING
%
Current overload count remaining until a motor overload fault/overload
occurs
49
LAST MOTOR
OVERLOAD
REMAINING
%
Last reading of motor overload left before power down
50
LAST DRIVE
OVERLOAD
REMAINING
%
Last reading of drive overload left before power down
51
SPEED MEASURED
RPM
Displays measured speed from encoder or resolver even if control type
is V/F or open vector
52
ACTIVE PARAM TBL
Active Parameter Table. – Parameter table currently in use on the drive
53
EE VER
Power Base EEPROM Rev. - Power base EEPROM parameter revision
number. Set by factory
54
FPGA VER
Power Base FPGA Rev. - Power base FPGA revision control number.
Set by factory
55
ACC/DEC DEMAND
Hz/SEC
Accel/Decel Demand. - Current ramp rate used by the velocity profiler
56
ID CURRENT
ID Current. - D axis measured current proportional to motor flux
57
ID DEMAND
A
ID Demand. - D axis demand current proportional to motor flux
58
IQ CURRENT
A
IQ Current. - Q axis measured current proportional to motor torque
59
IQ DEMAND
A
IQ Demand. - Q demand current proportional to motor torque
60
POWER FACTOR
Power Factor. - Ratio of (real power)/(apparent power)
61
PHASE 1 CURRENT
A
Phase 1(U) Current. - Phase U current
62
PHASE 2 CURRENT
A
Phase 2(V) Current. - Phase V current
63
PHASE 3 CURRENT
A
Phase 3(W) Current. - Phase W current
64
VD DEMAND
V
VD Demand. - D axis voltage demand for setting up motor flux
65
VQ DEMAND
V
VQ Demand. - Q axis voltage demand for setting up motor torque
66
ELECTRICAL ANGLE
°
Electrical Angle. - Electrical angle used to develop phased voltages to
the motor
67
MOTOR SPEED
RPM
Motor Speed. - Current speed of the motor
68
AT TEST DESC
Autotune Test Description. - Description of current autotuning state
Table 12-1 Monitor Parameters Descriptions Continued
Summary of Contents for VS1GV21-1B
Page 1: ...10 11 Installation Operating Manual MN765 VS1GV AC Closed Vector Control...
Page 12: ...2 2 General Information MN765...
Page 16: ...3 4 Installing the Drive MN765...
Page 78: ...6 16 Using the Keypad MN765...
Page 132: ...9 14 Troubleshooting MN765...
Page 172: ...A 16 Technical Specifications MN765...
Page 200: ...E 2 Remote Keypad Mounting Template MN765...
Page 201: ...Remote Keypad Mounting Template E 3 MN765...