AvL Proprietary and Confidential
Content is Subject to Change without Notice
Page
134
of
195
NMEA Server Enable
4
Choice
Core
"No", "Yes"
Enables or disables the NMEA server on the controller
NMEA Server Interval
1
Integer
Core
0 to 65536
NMEA server broadcast interval in seconds
NMEA Server Message Source
4
Choice
Core
“Controller”,
“Echoed”
The source of the NMEA messages sent to the configured
port. “Echoed” indicates a message echoed from a GPS
device
NMEA Server Com Port
Settings
4
String
Core
-
Com port setting or TCP-IP port number to use for NMEA
server on the controller
6.8.2 Slide Motor Feed System
Note – Many of these options are found under the “Core” tab.
Long name
Level
Type
Category
Value Range
Documentation
SlideMotor Abs Enc Offset
4
Float
Sensor
-600.0 to
600.0
The offset in degrees to be added to the read position of
the absolute encoder.
SlideMotor Abs Enc Scale
Factor
4
Float
Sensor
-10000.0 to
10000.0
The scale factor that will be multiplied to the raw absolute
encoder or resolver value.
Slide Motor Enable
4
Choice
Feed
“No”, “Yes”
Slide Position Enable (No = slide is disabled)
Slide Motor Stow Position
4
Choice
Positioner
“None”, “1”,
“2”, “3”
Slide position to move to before a stow completes
SlideMotor Scale Factor
4
Float
Sensor
-10000.0 to
10000.0
The scale factor to divide by to produce the actual value.
SlideMotor Switch 1 (through
3) is Interlock
4
Choice
Sensor
“No”, “Yes”
Flag indicating the digital input as an interlock (blocks other
operations when set
Slide Position 1
4
Float
Modules
-100.0 to
100.0
Numeric slide position representing the left slide position
Slide Position 2
4
Float
Modules
-100.0 to
100.0
Numeric slide position representing the center slide
position
Slide Position 3
4
Float
Modules
-100.0 to
100.0
Numeric slide position representing the right slide position
6.8.3 Vector Compass
Long name
Level
Type
Category
Value Range
Documentation
Vector Compass Enable
1
Integer
Core,
Sensor
0 or 1
Flag indicating that the compass should be used and
powered (1 = powered)
Vector Compass Heading
Offset
4
Float
System
-180.0 to
180.0
The offset in degrees of the device
Vector Compass Com Port
4
String
System
-
The filename for the com port used
Vector Compass Com Port
Settings
4
Choice
System
“No”, “Yes”
The computer settings for the com port, in the form of Baud,
Data, Stop & Parity Bits (ie: 9600 8 1 0) where parity values
are 0 for none and 1 for even.
Vector Compass Reset
1
Integer
Sensors
0 or 1
Flag indicating that the compass should be reset. ( 1 = reset
now)
Vector Compass Scan Width
1
Float
Modules
0.0 to 400.0
Scan width used during a SatTant or 0.0 to disable SatTant
Vector Compass Separation
4
Float
Modules
0.0001 to
10.0