AvL Proprietary and Confidential
Content is Subject to Change without Notice
Page
12
of
195
1.3.6 Module – Device
A Device Module file enables inter-operability and communication between the controller and a specific
device. An example of this type of vendor device module would be one created specifically for the
iDirect Evolution 8000 Modem.
1.3.7 Module – Function
A Function Module enables specific unique functions in the controller. An example of a function module
is the Step Track Module.
More details on the software architecture can be found in Chapters 4, 6 and 7.
1.4 Controller Hardware Specification
The two basic AAQ Controller components are the ACU and the NAV RIOM.
ACU
Size: approximately 8.3” H x 7.4” W x 1.4” D
Weight: 3 lb.
Communication Ports: 2 RS-232 ports, 1 Ethernet port
LNB Voltage Output: 0, 13 VDC, 18 VDC
Input Power: 24 to 32 VDC, 14A maximum
Operating Temperature: -40°C to +60°C
Humidity: 0 to 95% RH Condensing
Environmental Protection: IP65
Circuit Protection: internal resettable 15A fuse
NAV RIOM (Remote Input Output Module)
Size: approximately 4” H x 1 7/8” W x 1 ½” D
Weight: 0.5 lb
GPS Receiver and Patch Antenna
Magnetic Compass, with error correction
Digital Inclinometer – 2 axes
Environmental Protection: IP66
Operating Temperature: -40°C to +60°C
Humidity: 0 to 100% RH Condensing