ENPS roChannel Guidelines
175
ENPS roChannel Guidelines
For ENPS systems, Command supports roChannel with roCreate and roMetadataReplace in the MOS
Communication service.
Here are guidelines for using roChannel:
•
Users can set the MOS Channel in the ENPS properties, and when the rundown is loaded, video
items will be assigned to that channel group. Only one entry is allowed, and users should not set
the MOS Channel to a graphic channel group; it is not necessary.
•
Users should add all channel groups that might be used to the system settings in Command.
Those settings are located in the System Settings dialog box under the MOS category in the
Channel Groups sub-category.
•
The channel group assigned in the MOS Channel will be the first one displayed in the Command
playlist. Other channel groups will be to the right of it.
In this example, omAB is defined in the ENPS MOS Channel, and therefore displayed first. Both
omAB and omC are defined in the system settings in Command.
•
If there are graphic channel groups, they will be displayed after the channel group set in the
MOS Channel.
In this example, the channel group omAB is set in the ENPS MOS Channel, and orad is a
graphic channel group. All three are defined in the system settings in Command.
•
Users can assign an individual item to a different channel group by changing the MOS Channel
in the rundown rather than the rundown properties.
If the rundown MOS Channel is set when the rundown is MOS activated, the item will keep its
channel designation. The rundown MOS Channel will not override the rundown’s MOS Channel.
•
Users can easily switch to a different channel group for a MOS Active/Ready to Air rundown by
opening the rundown properties and entering the new MOS Channel. Before the change is made
in ENPS, the operator must unlock the current channel group in Command, and then lock the
updated channel group after the change is made.
n
If you plan to use MOS Channel to change the channel group for any MOS Active rundown, you need
to define channel group in the MOS Channel field for all rundowns. If the MOS Channel is not
defined when the rundown is MOS activated, the MOS Channel needs to be set twice to make the
change happen.
Configuring Command for MOS Redirection
Command sites that interface with the ENPS newsroom computer system can run two MOS
Communication services and set the second one to have a different MOSID so that MOS redirection
can be used to send playlists to the backup server. The purpose of MOS redirection to allow users to