Material
Insertion loss (dB)
Glass, metal reinforced grid
10
Glass, metal clad sunguard
10
Wall, indoor, plaster, wood
2
Wall, brick, 10 cm
3.5
Wall concrete, 10 cm
6
Wall concrete, 15 cm
9
Wall concrete, 20 cm, large windows
6
Wall concrete, 40 cm
17
Ceiling, concrete, reinforced, tiles
17-20
With the DECT equipment, the available link budget is 38 dB. This is the maximum allowed
loss in the link, under constraints of excellent and good speech quality and the ability for the
user to move.
To calculate the distance between DAP and handset, use the information in
on page 38.
Using the building map, start at the possible DAP location. Move away from the DAP location.
Calculate the distance. When you encounter an obstacle, calculate the insertion loss. Using
the chart below, start in the lower left corner (0,0), move horizontally, to the value for the actual
distance. Move vertically to the value for the insertion loss of the encountered obstacle. If the
curve in the chart is crossed, read the maximum distance for that specific DAP in that situation.
This gives the cell size in that specific direction. Ensure that outside the calculated range
communication is possible but a good voice quality is no longer guaranteed.
Site planning
SIP DECT Fundamentals
October 2012 37
Summary of Contents for CS 1000
Page 6: ...6 SIP DECT Fundamentals October 2012 ...
Page 146: ...System administration 146 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 174: ...System maintenance 174 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 204: ...Site survey example 204 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...