ECEMSUP Example
Rung 1: The ECOM100 Config IBox is responsible for coordination/interlocking of all
ECOM100 type IBoxes for one specific ECOM100 module. Tag the ECOM100 in slot
1 as ECOM100# K0. All other ECxxxx IBoxes refer to this module # as K0. If you need to
move the module in the base to a different slot, then you only need to change this one IBox.
V400 is used as a global result status register for the other ECxxxx IBoxes using this specific
ECOM100 module.V401 is used to coordinate/interlock the logic in all of the other ECxxxx
IBoxes using this specific ECOM100 module. V402-V502 is a common 130 byte buffer
available for use by the other ECxxxx IBoxes using this specific ECOM100 module.
K1
K0
V400
V401
V402 - V502