NOTE: Status flags are valid only until another instruction uses the same flag.
In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator
using the Load instruction. The value in the accumulator is ORed with V2006 using the OR
instruction. The value in the lower 16 bits of the accumulator is output to V2010 using the
Out instruction.
OR
A aaa
3
D
OR (V2006)
Handheld Programmer Keystrokes
LD
V2000
X1
Load the value in V2000 into
the lower 16 bits of the
accumulator
OR
V2006
Or the value in the
accumulator with
the value in V2006
OUT
V2010
Copy the value in the lower
16 bits of the accumulator to
V2010
0 0 1 0 1 0 0 0 0 1 1 1 1 0 1 0
0 1 1 0 1 0 1 0 0 1 1 1 1 0 1 0
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0
V2000
2
8
7
A
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The upper 16 bits of the accumulator
will be set to 0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Acc.
Acc.
0 0 1 0 1 0 0 0 0 1 1 1 1 0 1 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Acc.
0 1 1 0 1 0 1 0 0 0 1 1 1 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
6A38
V2010
6 A 7 A
Direct SOFT32
STR
$
1
B
ENT
SHFT
ANDST
L
2
C
0
A
0
A
0
A
ENT
SHFT
AND
V
2
C
0
A
0
A
ENT
6
G
OUT
GX
SHFT
AND
V
2
C
0
A
1
B
0
A
ENT
OR
Q
0
Operand Data Type
DL06 Range
A
aaa
V-memory
V
See memory map
Pointer
P
See memory map
Discrete Bit Flags
Description
SP63
ON if the result in the accumulator is zero.
SP70
ON if the result in the accumulator is negative
DS
Used
HPP Used
Direct
SOFT
Or (OR)
The Or instruction is a 16-bit instruction that logically ORs the
value in the lower 16 bits of the accumulator with a specified
V-memory location (Aaaa). The result resides in the accumulator.
The discrete status flag indicates if the result of the OR is zero.