1.800.944.4283 AutoGate Technical Support
Mar 6, 2019
39
AUXILIARY RELAYS A & B
OPTIONS:
OFF
Pulse on OPEN Limit: 2-second Relay Activation
Pulse on CLOSE Limit: 2-second Relay Activation
Hold on OPEN Limit: Latches Relay ON during OPEN Limit
Hold on CLOSE Limit: Latches Relay ON during CLOSE Limit
Pulse on Motor OPEN: 2-second Pulse when Drop arm/gate starts to move OPEN
Pulse on Motor CLOSE: 2-second Pulse when Drop arm/gate starts to CLOSE
Hold on Motor OPEN: Latches Relay on when Drop arm/gate is OPENING
Hold on Motor CLOSE: Latches Relay ON when Drop arm/gate is CLOSING
P12
P13
AUX Relays A & B: Are programmable for operation based on gate action or position. Both relays
The Genesis board has (2) 24VDC outputs and (2) 12VDC outputs to power external devices. Each is fused at 2 AMPS.
24VDC
ACCESSORY Power (2) Fused at a total of 2 Amps
12VDC
ACCESSORY Power (2) Fused at a total of 2 Amps