30
Typical 24V series connection
1) Jumper wire from battery
1 NEGATIVE is connected
to battery 2 POSITIVE.
2) Wire from battery 1 POSI-
TIVE to POSITIVE terminal
on control board
3) Wire from battery 2 NEGA-
TIVE to NEGATIVE terminal
on control board.
Batteries will charge when AC power or Solar Panels are present and power gate automatically without any changes in
wiring. Note: Solar applications will require a program selection in the board menu (see page
??
.
The Genesis controller has a built-in battery charging system that has multiple formats. The charging sequence can
handle full size flooded batteries as well as sealed lead acid or AGM batteries. The Genesis primary input voltage can
also be connected directly to solar panel(s) for non-AC operation. The built-in charger when programmed for solar will
allow the system to run off the batteries and will still charge them during the daylight hours.
Install Two (2) 12 VDC Batteries (Required, not provided) on the battery shelf. AutoGate recommends Group 24 Deep
Cycle Marine Starting batteries for extended battery back up. At a minimum use (2) 7AH batteries for battery back up.
Install an approved 8’ earth ground rod 6” to 3’ off the rear side of operator pad*. The Ground wire connection is
located inside the door. Recommended wire is #8 gauge or larger. NEVER splice the ground wire!
Improper grounding will make the operator more susceptible to lightening or surge damage and can affect
GENESIS Board or accessories.
1
2
*Check national and local
codes for proper depth.
To Operator
Summary of Contents for Shield M30 Series
Page 33: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 33 ...
Page 42: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 42 ...
Page 43: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 43 ...
Page 44: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 44 ...
Page 45: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 45 ...
Page 46: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 46 ...
Page 47: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 47 ...
Page 48: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 48 ...
Page 53: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 53 ...