Close the operator doors and latch them in the closed position so they do not swing open while moving, lifting
or adjusting the operator. Using a forklift, with side-shift if possible, insert the forks into the channel receivers
on the door side of the operator.
Lift the Linkage Arm at the
center point 4-6 inches to re-
lease the Drop arm/gate
(shown below).
Push the gate open until it rests against the T/M Safety Pin now positioned in the second set of T/M bracket
holes (position #2).
From the public side, position the operator in front of the raised concrete pad. Carefully raise the system
enough to clear the Bolsters. Slowly advance and lower once the Drop arm/gate is centered between the op-
erator end Bolster as shown below. Once lowered, side shift the system to position the operator end barrier
arm pin to be 50% “engaged in the pin cup. Fully lower the system leaving the forklift in place. By design, the
YOKE END pin will NOT be 50% in the pin cups.
PREPERATION, ATTACHING THE DROP ARM, & OPERATOR INSTALATION
Summary of Contents for Shield M30 Series
Page 33: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 33 ...
Page 42: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 42 ...
Page 43: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 43 ...
Page 44: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 44 ...
Page 45: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 45 ...
Page 46: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 46 ...
Page 47: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 47 ...
Page 48: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 48 ...
Page 53: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 53 ...