1.800.944.4283 AutoGate Technical Support
Mar 6, 2019
36
Type B2 (contact)
Contact Edge S
ensors
Close or Closing
Contact edges on the bottom of the gate are often added
as an extra entrapment device for the closing mode. We
do not recommend a contact edge to be the only external
entrapment device for the closing mode.
Open Edge
Close Edge
Programmable Inputs (x2)
Approved Edge Sensor Devices:
Miller Edge CPT 223, ASO SENTIR 15-10VT, 45 STKS4
Open or Opening
Your Vertical Pivot operator now requires a minimum of (1) OPEN obstruc-
tion device to be wired to the Genesis Control board to operate. You may
use any approved device listed above. The face and the throat area are
required to be protected per UL325 7th edition.
NOTE:
The two programmable inputs can be configured as either edge or beam and as either open or close.
MONITORED DEVICE CONNECTIONS POINTS