1.800.944.4283 AutoGate Technical Support
Mar 6, 2019
37
In addition to the entrapment sensor inputs there are operational inputs for vehicle detection, communication with another gate
or similar device as well as push buttons for control of various modes of operation.
INPUT NAME
FUNCTION AFTER MOMENTARY TRIGGER
FUNCTION DURING
CONTINUOUS TRIGGER
Shadow Loop
While at open limit, hold open, ignore once off of the open limit
switch. (Not common on Vertical Pivot Gate)
Hold Open
FE/Back (Free
Exit/ Back Away)
Opens Drop arm/gate as Open1, but when signal is removed, Drop
arm/gate is given command to close. (Close command over ridden
by any other open or Reverse/Interrupt command or stop com-
mand) (Primarily designed to work with FE/Back on standard traffic-
Barrier Arms)
Starts opening movement from
any position
Close Loop
Start closing movement from any position, Open commands can
override.
If Drop arm/gate is closing when activated, Drop arm/gate
stops until clear and then continues to close
.
Close input responds on release of the input normally.
Close input will hold the Drop arm/gate open while input is main-
tained with the Drop arm/gate in the open position.
When in constant pressure mode, close input responds on initial
press. (Not common on Vertical Pivot Gate)
If held in upward motion, no
effect.
If held in downward motion,
gate movement is paused until
released and continues down-
ward on release
Reverse/
Interrupt
When closing, stops and re-opens.
If held, stay open
Open / Close
PGM
When menu option not enabled, Input = open 1 only. When ena-
bled, input = Open 1 unless the open limit is reached, it then turns
to Close.
If input is held during OPEN, Drop arm/gate holds open.
Input needs to cycle off before input can CLOSE Drop arm/gate.
If held it remains in its state
Open 1
starts opening movement from any position
starts opening from any position
Open 2
starts opening movement from any position
Same as above
Fire Open
Absolute open, until the board is hard power reset, or local reset
button pushed
Locks Drop arm/gate open until
released
Stop
Stops gate at any point and cancels current inputs. Inputs will be
ignored until stop is released. A stop input will disable the auto-
close timer
If held, no Drop arm/gate move-
ment, inputs ignored.
P2
Summary of Contents for Shield M30 Series
Page 33: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 33 ...
Page 42: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 42 ...
Page 43: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 43 ...
Page 44: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 44 ...
Page 45: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 45 ...
Page 46: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 46 ...
Page 47: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 47 ...
Page 48: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 48 ...
Page 53: ...1 800 944 4283 AutoGate Technical Support Mar 6 2019 53 ...