21
Possible faults
Before each fault elimination:
Switch off device.
Pull out power plug
Problem Possible
Cause
Remedy
Logs are not being split properly
(insufficient splitting performance)
The log is not positioned correctly
The log exceeds the maximum
dimensions or the wood is too hard
for the performance of the machine
Splitting blade does not split log
Oil leak
Hydraulic pressure too low
Incorrect connecting lead (longer
than 10 m or too small cable cross-
section).
Reposition the log correctly
Cut the log to the required dimensions
Sharpen splitting blade, check for burrs or notches
Place a sheet of cardboard under the log splitter in
order to locate the leak. To correct the problem, re-
fer to the manufacturer
Check the oil level and add more oil if necessary
If the problem cannot be rectified, refer to the man-
ufacturer
Use the correct connecting lead
Splitting blade extends wobbling or
with strong vibrations
Air in the circuit
Splitting column not sufficiently
lubricated or oiled
Open oil tank cap
Check the oil level and add more oil if necessary
Lubricate splitting column or oil with environmental-
ly friendly spray oil.
If the problem cannot be rectified, refer to the man-
ufacturer
Splitting blade does not extend
Hydraulic pump defective
To correct the problem, refer to the manufacturer
Motor starts, but the splitting blade
does not extend
Motor turns in wrong direction
Check the motor direction
Threephase: adjust the motor direction
Motor does not start
No power supply.
2-phase mode in threephase mo-
tor.
Mains cable defective.
Electric motor defective
Check fuses.
Have fuse and lead checked by qualified electri-
cian.
Replace the connection cable or have it checked by
an electrician
To correct the problem, refer to the manufacturer
In case of further faults or inquiries please contact your local dealer.
Summary of Contents for ASP 10 TS-2
Page 12: ...12 Schaltplan Hydraulikplan Technische Änderungen vorbehalten ...
Page 33: ...33 Schéma électrique Schéma hydraulique Sous réserve de modifications techniques ...
Page 54: ...54 Schéma zapojení Schéma hydraulické Technické změny vyhrazeny ...
Page 64: ...64 Kredsløbsdiagram Hydraulikplan Der tages forbehold för tekniske ændringer ...
Page 75: ...75 Diagrama electrónico Plano hidráulico Reservado el derecho a modificaciones técnicas ...
Page 85: ...85 Kytkentäkaavio Hydrauliikkakaavio Oikeus teknisiin muutoksiin pidätetään ...
Page 116: ...116 Schema elettrico Schema impianto idraulico Con riserva di apportare modifiche tecniche ...
Page 137: ...137 Schemat połączeń Schemat hydrauliczny Zastrzega się wprowadzanie zmian technicznych ...
Page 148: ...148 Schema circuitului electric Schema hidraulice Se rezervå dreptul la modificåri tehnice ...
Page 158: ...158 Kopplingsschema Hydraulikschema Förbehåll för tekniska förändringar ...
Page 168: ...168 Schéma zapojenia Schéma hydrauliky Technické změny vyhradené ...
Page 179: ......
Page 182: ......
Page 183: ......