Software Option Parameters
After the hardware option switches are set, a terminal should be connected
to the modem so that the following software parameters can be set:
•
For all modems, type atzo12=y and press [Enter] twice.
•
all modems, type atzo34=1 and press [Enter] twice.
•
Depending on the value (y or n) in column 07 of the table in the
previous section, type atzo7=y or atzo7=n and press [Enter] twice.
•
For all modems, type at atzo51=y and press [Enter] twice.
The parameter meanings are as follows:
o7
(o7 = y or o7 = n) Automatic answer enabled (yes or no)
o12
(o12 = y) Transparent data mode (should be enabled)
o34
(o34 =1) Operate as standard modem without error control
o51
(o51 = y or o51 = n) CTS controlled by RTS (yes or no)
Locking Option Changes
After the software option parameters have been set, hardware switch S1-2
should be changed from D to U to lock the options so that they cannot be
changed.
2-60 Hardware Installation and Maintenance