717
(SYS_FAIL), MAJOR
MTC cannot <string> for card <device>, return= <integer>,
errno = <integer>.
Maintenance failed a system call. This is an indication of system
problems.
•
Try stopping and restarting the Voice System or rebooting the
system.
718
(NO_CLOCK), MAJOR
MTC cannot find clock on card <device>.
Maintenance detected no clock on a system-master board. This is an
indication of hardware problems. The board may need to be
replaced.
•
Try removing the device from service and rebooting the system.
If the device passes initial boot diagnostics, you may then restore
the device.
722
(GET_SEMA), MAJOR
MTC cannot acquire the semaphore.
Maintenance cannot create the semaphore. This is an indication of
system problems.
•
Try stopping and restarting the Voice
system.
723
(SET_SEMA), MAJOR
MTC cannot set the semaphore.
Maintenance cannot lock the semaphore.
software problems.
•
Try stopping and restarting the Voice
system.
System or rebooting the
This is an indication of
System or rebooting the
APPENDIX: System Messages
A-31