DS300f G2 Series User Manual
224
Synchronization is completed
No action is required.
Synchronization is paused
Resume synchronization when ready.
Synchronization is resumed
No action is required.
Synchronization is stopped
Synchronization is aborted due to an internal
error.
Reduce system load on the
ASUS DS300f G2
.
Synchronization is queued
No action is required.
Synchronization is stopped internally
Subsystem (
ASUS DS300f G2
)
The Subsystem is started
No action is required.
The Subsystem is stopped
Subsystem parameter(s) are changed by user
System is set to Redundant mode
System is set to Critical mode
Check controller operation.
Enclosure has only N PSU left
Check to make sure each enclosure has three or more
operational PSU. (N=2 for ASUS DS300f G2 and
DS300j G2 models)
Enclosure has only N-1 PSU left
System is set to Non-Redundant mode
If your system has two controllers, check controller
operation.
Transition
Transition is started
No action is required.
Transition is completed
Transition is paused
Resume transition when ready.
Transition is resumed
No action is required.
Transition is stopped
If this action was not intentional, check the disk array’s
status.
Transition was switched to rebuild
Replace the dead physical drive or reinstall the missing
drive.
Unknown
Unknown priority reason is detected
If this message appears repeatedly, contact Tech
Support.
Zoning
Zoning permission settings with the expander
has been reset to defaults
No action is required.
Zoning expander has been rebooted.
Zoning permission settings with the expander
different than expected
Settings have been updated correctly. No action is
required.