Shelf Management Alarm Module
AXP1440 Installation and Use (6806800H23U)
147
7.7
Hot Swap Interface
The SAM provides a hot swap interface allowing the SAM to be replaced without powering
down the shelf. The hot swap interface is implemented using the shelf manager mezzanine
CPLD device. The interface is composed of three components:
Injector/ejector handle switch
Presence signal indicating that the SAM is fully seated in its backplane connector
HS LED to indicate safe to remove state
7.8
Power
The SAM uses dual +12V power feeds, one from each PEM. Hot swap circuitry ensures correct
operation when a SAM is inserted into or removed from a live system.
7.9
SAM Software
The software that runs on the shelf manager is described in detail in the
Pigeon Point Systems
IPM Sentry Shelf Manager User Guide
, which provides an introduction to shelf management, the
shelf manager, and the shelf management mezzanine. Also available is the
Pigeon Point Systems
IPM Sentry Shelf-External Interface Reference
which describes the command line, web, SNMP
(Simple Network Management Protocol), and RMCP (Remote Management Control Protocol)
interfaces. Refer to
for more information on these publications.
7.9.1
imls Utility
A utility called imls is available on the SAM. It can be used to list all firmware images present in
flash. Note that the Shelf Manager flash is divided into two banks. Each bank contains a set of
three separate firmware images:
U-Boot
RFS
Kernel images
When the rupgrade_tool utility is used to perform a reliable firmware upgrade operation on
the Shelf Manager, the flash bank that is currently not active is programmed with the new
images, the processor is reset, and the newly programmed flash bank is selected.
Summary of Contents for AXP1440
Page 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Page 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Page 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Page 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Page 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Page 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Page 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Page 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Page 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Page 155: ...1...