Shelf Management Alarm Module
132
AXP1440 Installation and Use (6806800H23U
)
7.4.1
IPMB Connectivity
The IPMB is a dual radial topology. Each IPMC in the shelf connects to both SAMs for a
redundant IPMB.
7.4.2
RS-232 Serial Interface
The SAM provides an RS-232 interface on the face plate connector using an RJ-45 connector.
The connector is routed to the serial port of the shelf manager mezzanine.The default baud
rate is 9600, 8, N, 1. Pin assignments for this connector are:
The SAM provides an RS-232 interface on the alarm display panel at the front of the chassis
utilizing a mini-D 9pin connector. The connector is routed to the second serial port of the shelf
manager. The baud rate is 115200, 8, N, 1 and cannot be changed. Pin assignments for this
connector are:
Table 7-1.
RJ-45 Serial Port Connector
Pin
Signal
Direction
1
DSR
Input
2
DCD
Input
3
DTR
Output
4
GND
5
RXD
Input
6
TXD
Output
7
CTS
Input
8
RTS
Output
Table 7-2.
Alarm Display Panel (ADP) Serial Port Connector
Pin
Signal
Direction
1
No Connect
2
RXD
Input
Summary of Contents for AXP1440
Page 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Page 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Page 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Page 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Page 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Page 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Page 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Page 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Page 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Page 155: ...1...