Shelf Management Alarm Module
AXP1440 Installation and Use (6806800H23U)
139
7.5.2
Redundancy Control
The ShMM-1500R supports redundant operation with automatic switchover using a redundant
ShMM-1500R. In a configuration where two ShMM-1500Rs are present, one acts as the active
shelf manager and the other as a standby. Both ShMM-1500Rs monitor each other, and either
can trigger a switchover if necessary.
The ShMM-1500R provides a number of hardware redundancy signals on the CN1 connector.
The HRI is implemented using the FPGA device.
7.5.2.1
Hardware Redundancy Interface
The hardware redundancy signals of the ShMM-1500R are implemented as follows:
Cross connected ShMM-1500R present input (PRES_R#) and output (PRES_L#)
Cross connected ShMM-1500R status 0 input (SHMM_STATUS0_R) and output
(SHMM_STATUS0_L)
Cross connected redundant ShMM-1500R status 1 input (SHMM_STATUS1_R) and
output (SHMM_STATUS1_L)
Active output (ACTIVE#) that can be used on the ShMM-1500R carrier to enable
interfaces that must be exclusively driven by the active ShMM-1500R
Bi-color status LED
The ACTIVE# signal is intended for use on a carrier and is not connected directly to the peer-
ShMM through the backplane. The cross-connected ShMM-1500R status signals are
asynchronous serial bit streams that are transmitted to the peer-ShMM by the FPGA and
communicate the following information: Health status, Switchover Requests, PRES_R state,
Active state, watchdog timer status, parity and other TBD data. An identical copy of the bit
stream is also sent on the redundant ShMM-1500R status signal. This information is used by the
FPGA to ensure that only one of the two connected ShMM-1500Rs goes into active mode at a
time.
shows the HRI of the ShMM-1500R.
90
7600 Inlet, 5000 /-5%
100
8000 Inlet, 5200 /-5%
Fan Level
Speed in RPMs
Summary of Contents for AXP1440
Page 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Page 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Page 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Page 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Page 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Page 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Page 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Page 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Page 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Page 155: ...1...