FRU Installation
110
AXP1440 Installation and Use (6806800H23U
)
Procedure - No Installed Front Blade
The following procedure describes the installation of the RTM without a front blade installed.
1. Locate the slot the RTM is to be installed into the shelf's rear which must be the same
as that of the front blade.
2. Ensure that the top and the bottom handles of the RTM are in an outward position by
squeezing the lever and the latch together.
3. Insert the RTM into the shelf by placing the top and bottom edges in the card guides
of the slot.
4. Slide the RTM into the slot.
5. Apply equal and steady pressure to the RTM to carefully slide the RTM into the shelf
until you feel resistance. Continue to gently push the RTM until the RTM connectors
engage.
6. Squeeze the lever and the latch together and hook the lower and the upper handle
into the shelf rail recesses.