CS175-275-575-875 Installation Guide
93
Frequency
433 MHz for the RX8i4 and RX16i4
Current draw
20 mA Maximum
Operating temperature
0 to 49 °C
Dimensions
11 cm wide * 8.1 cm high * 2.54 cm deep
Shipping weight
95 g
16.4 Programming the RX8i4-16i4
In order to program the Rx8i4-16i4 you must do the following:
•
Determine the transmitter settings: determine the different settings for the wireless
sensors.
•
Enroll the modules: set-up the module to be supervised by the CSx75 control panel.
•
Program the module: put the module into program mode so you can start
programming the transmitters and enter the settings for transmitters and partitions.
16.4.1 Determine transmitter settings
When programming wireless transmitters into the module, there are various options and
partitions you can set for each transmitter. These settings appear in the segments of each
programming location. The default settings shown for segments 1 and 2 apply to all zone
locations from 1 to 168.
16.4.2 Special settings for door/window transmitters and wireless smoke detectors.
Use the following guidelines when setting feature 4 and 5 for door/window transmitters
and wireless smoke detectors.
•
Feature 4, input option 1:
•
For door/window transmitters, turn this feature on to disable the internal reed
switches.
•
For wireless smoke detectors with tamper switches, turn this feature on to
enable the tamper feature.
•
This option must be off (disabled) when using wireless smoke detectors without
tamper switches.
•
Feature 5, input option 2:
•
For door/window transmitters that use a normally open external contact, leave
this feature off (N/O).
•
For door/windows transmitters that use a normally closed external contact, leave
this feature on (NC).
Location 0
Learn-in mode
This location is used to learn in devices. The segment used refers to the zone number
required.