CS175-275-575-875 Installation Guide
18 CS216
H
ARDWARE ZONE EXPANDER
The CS216 is a microprocessor-controlled 16-zone expander for the CSx75 control panel.
Up to 20 CS216 expanders can be added to the CSx75 control panel with a maximum
zone count of 168 zones. Each expander has an optional tamper switch and power
isolator making it ideal for use in a remote location.
"
Roller switch zones can only be used on the CSx75 control panel. They cannot be used
on a CS216 hardware zone expander.
1
Zone connections (16
sets)
4
Additional keypad bus
connection
7
DIP switches (6
positions)
2
Tamper connection
(required)
5
No function
8
Processor
3
Keypad bus
connection
6
Supervision LED
18.1
Setting the DIP switches
Decide the starting zone of each zone expander. The starting zone must be on a
boundary of eight zones. The 16 zones for this module will move out from this starting
position. There are stick-on zone labels to indicate the zone numbers that you select.
To set the starting zone, set the DIP switch according to the table below.
"
The position of all switches is updated only when the CS216 is powered up. Before you
change the position of these switches you must power down the expander.
CS216
DS 1
DS2
J1
DATA
AUX+
VOUT
TAM
1 2 3 4 5 6
NO
S1
CO
M
C
O
M
Z1
1
Z1
2
Z1
3
Z1
4
Z1
5
Z1
6
Z1
7
Z1
8
Z1
9
Z2
0
Z2
1
Z2
2
Z2
3
Z2
4
5
Z1
0
Z9
1
2
3
4
6
7
U3
8
DATA
Not used
AUX+