CS175-275-575-875 Installation Guide
121
20.3 Programming the CS507
20.3.1 Programming the output configuration and partition
Location 0
Programming the event, zone and time for output 1 (three segments, ND)
This location is used to select the particular function, zone number and time for an output
to trip.
Segment 1 (EVENT)
Selects the event that triggers the output. See the table
below for the specific events that can be selected.
Segment 2 (ZONE/USER)
Selects the zone or user number necessary to trigger an
output. If 0 is programmed in this location, any zone or user
activates the output.
Segment 3 (TIME)
Selects the amount of time an output remains activated
when an output triggers. If 0 is programmed in this location,
the output follows the particular event.
#
Event
#
Event
#
Event
0
Burglary Alarm
18
Entry
36
Program Mode
1
Fire Alarm
19
Exit
37
Download
2
24-hour Alarm
20
Entry or Exit
38
Ground Fault
3
Zone Trouble
21
Armed
39
Over Current
4
Zone Tamper
22
Not Armed
40
Box Tamper
5
Burglary Siren
23
Ready
41
Siren Tamper
6
Fire Siren
24
Not Ready
42
Any Zone Faulted
7
Any Siren
25
Fire
43
Any Alarm
8
Zone Bypass
26
Fire Trouble
44
Keypad Beeping
9
AC Failure
27
Chime
45
Code Entry
10
System Low Battery
28
Expander Trouble
46
Key FOB Function 1
11
Duress
29
Dynamic Battery Test
47
Key FOB Function 2
12
Manual Fire
30
Open Schedule
48
Auto Arm Control
13
Aux 2 Keypad
31
Closed Schedule
49
Auto Disarm Control
14
Keypad Panic
32
Listen In
50
Auto Arm and Disarm Control
15
Keypad Tamper
33
Line Seizure
51
Follow schedule of CS507
16
Automatic Test
34
Failed to Communicate
52
Flash X-10 for Alarm Memory
17
Alarm Memory
35
Telephone Line Fault
53
Flash X-10 for Siren
See loc. 65 and 66 in CSx75