72
CS175-275-575-875 Installation Guide
and
99
(answer incoming call for download) functions.
3
Reserved
4
Enable walk-test mode
5-8
Reserved
Location 54
Go to program code (six segments, ND)
This location contains the Go to program code, which is either a four-digit or six-digit code.
If the six-digit code option is enabled in location 53, this code must contain six digits. If the
option is not enabled, the last two segments (digits) are ignored. When the CSx75 is
disarmed, the Go to program code can be used to enter programming
mode.
Location 55
Go to program code partition and authorization (two segments, feature selection)
The Go to program code can be used as a standard arm/disarm code. When using the
code to arm or disarm, the user ID is 255. This code may not be changed in run mode.
Segment 1
1
Reserved
2
On: enables the Go to program code as an arm only code.
3
On: enables the Go to program code as an arm only after
closing code.
4
On: enables the Go to program code as a master arm/disarm
code that can change user codes.
5
On: enables the Go to program code as an arm/disarm code.
6
On: enables the Go to program code to bypass zones.
7
On: enables the Go to program code to send opening and
closing reports.
8
Reserved
Segment 2
1
On: enables the Go to program code for partition 1.
2
On: enables the Go to program code for partition 2.
3
On: enables the Go to program code for partition 3.
4
On: enables the Go to program code for partition 4.
5
On: enables the Go to program code for partition 5.
6
On: enables the Go to program code for partition 6.
7
On: enables the Go to program code for partition 7.
8
On: enables the Go to program code for partition 8.
Location 56
Duress code (six segments, ND)
This location contains the duress code. It has either four or six digits. If the six digit code
option is enabled in location 53, this code must contain six digits. If the six-digit option is
not enabled in location 53, the last two digits are ignored. If the duress code is
programmed, it works for all partitions.