48
CS175-275-575-875 Installation Guide
Steps
1. Press
6
.
2. Enter a master user code. The keypad prompts you to enter a user number.
3. Enter a two-digit user number. The Ready LED is constant and the Bypass LED
flashes.
4. The illuminated LEDs indicate the authority levels assigned to the selected user.
An explanation of the LEDs is listed in the following table. Press the relevant
number to turn an authority level on or off.
User Attributes : if LED8 is OFF
LED1
Reserved. Do not change if on.
LED2
Arm Only
LED3
Arm Only After Close Window.
LED4
Master arm/disarm (can program other codes).
LED5
Arm/disarm code.
LED6
Allowed to bypass zones.
LED7
Code will send open / close reports.
LED8
If this LED is on, this code is programmed as a function
code. Do not change, Press [#] - [#] to exit.
User Attributes : if LED8 is ON
LED1
Activate output #1
LED2
Activate output # 2
LED3
Activate output # 3
LED4
Activate output # 4
LED5
Arm/disarm
LED6
Bypass zones
LED7
Open/Close peporting
LED 8
If this LED is off, LEDs 1 to 7 indicate the attributes listed
the table above.
5. Press .
6. The partition enable section is displayed. This tells the system the partition the
selelcted user can arm/disarm. To change any of these numbers, press 1 to 8 to
permit or deny access to the user.
7. LEDs 1 to 8 illuminate the partitions the user can access. To deny the user
access to a partition, press the relevant number on the keypad. For example, if