CS175-275-575-875 Installation Guide
151
26 A
PPENDIX
4: S
ERVICE MESSAGES
Message
Explanation
Control Over-current
A short circuit of a control panel’s power supply has
occurred.
Control Siren Trouble
Open circuit has occurred on the bell or siren circuit.
Control Box Tamper
(Optional) The box tamper circuit has activated.
Control Phone Trouble
A phone line connected to the control is not operating
properly.
Control Fail to comm.
The control tried to send a message to the central station,
but failed.
Control Ground Fault
A short to ground has been detected on a control circuit.
Control Loss of Time
The system has lost total power and needs the clock reset.
Control Power Trouble
The mains power to the system is not on.
Control Low Battery
The standby battery is low.
Expansion Over-current
A short circuit of an expansion device’s power supply has
occurred.
Expansion Aux. Comm. Fail
An auxiliary reporting device has failed to communicate.
Expansion Power Trouble
The mains power to an expansion power supply is not on.
Expansion Low Battery
An expansion power supply has a low battery
Expansion Box Tamper
A box containing an expansion device has been opened.
Expansion Trouble
An expansion device or keypad is not reporting to the
control panel.
Expansion Siren Trouble
Open circuit has occurred on the bell or siren circuit of the
expander.
Zone Tamper, Press
A zone is tampered. Press to identify the tampered zone.
Zone Low Batt, Press
A wireless device has a low battery. Press to identify the
zone.
Zone Lost, Press
A wireless zone device is not reporting to the control. Press
to identify the zone.
Zone Trouble, Press
A zone has some form of trouble (probably wiring). Press
to identify the zone.