CS175-275-575-875 Installation Guide
49
LED 2 is lit, the user can access partition 2. Press
2
to deny the user access to
the partition and to turn off LED 2.
8. Press
to save the changes. The keypad prompts you to enter another user
code.
9. To edit another user’s authority level, return to step 3. Otherwise, press
#
to exit.
"
Any master arm/disarm code can add or change a user code if the master code has
access to the same partitions as that code.
When programming user codes for a partitioned system, leave at least one code with
access to all partitions to allow new users to be added. This can be the Go to program
code if it is enabled in Location 55. To allow a user add new codes, remove the partition
authority from all blank codes.
10.3.9 Calling back for download
Press
98
while the system is disarmed, to perform a call back for a download.
"
A valid user code may be required after
98
if this option is enabled in location 53. See
Location 53 on page 71 for more information.
10.3.10
Seizing the phone line for download
Press
99
while the system is disarmed, to make the control panel seize the phone line
for a download.
"
A valid user code may be required after
99
if this option is enabled in location 53. See
Location 53 on page 71 for more information.
10.3.11 Memorising
tamper-alarms
Indications of tamper alarms from a detector or housing can be reset only in programming
mode. This means that only the installer can reset tampers.
10.3.12
Blocking tamper alarms
Tamper alarms from a detector or housing are blocked and are not transmitted to the
central station when the system is in programming mode. This allows you to test and
maintain the system without causing unnecessary tamper alarms.
10.3.13
Blocking the keypad due to too many incorrect codes
The CSx75 can be programmed to block the keypad for 60 seconds and send a tamper
alarm to the central station when more than 30 keypresses are made on a keypad without