4. Enter the new user code for the selected user. If you are changing the current
code, use the scroll keys to select the digit to change and then enter the correct
number. If the code is rejected, the sounder beeps three times.
To delete a user
code, press
for a four-digit code or
for a six-digit code.
5. To edit another user code, return to step 2 and enter the user code.
6. Press
#
to exit.
10.2.9 Assigning authority level
You must assign user codes before assigning authority levels. To set a user’s acess to a
particular partition, you must have access to the partition.
Steps
1. Press
6
.
2. Enter a master user code. The keypad prompts you to enter a user number.
3. Enter a two-digit user number. For example, 03 is user 3.
4. Set the attributes in the following table for the selected user. Press
0
to turn an
attribute off. Press
1
to turn an attribute on.
•
When programming codes that activate outputs, you must also configure the
output events. See
Location 59
on page 73 for more information.
•
When you set Outputs Used? to 1, the options Output 4, Output 3, Output 2
and Output 1 are displayed. Press to continue without editing these options.
User Attributes
Outputs used?
Output 4 ?
Output 3 ?
Output 2 ?
Output 1?
Open / Close Rprt?
Bypass enable?
Arm / Disarm?
Master code?
Sched arm only?
Arm only?
5. Press . The partition enable
section is displayed. The keypad displays the
partitions the selected user can access.