CS175-275-575-875 Installation Guide
65
Location 33
Download call back number (16 segments, ND)
If a telephone number is programmed in this location and Require Call Back is enabled in
location 32, the control panel hangs up for approximately 36 seconds to ensure that the
calling party has disconnected and then calls back. See
Location 1
on page 61 for tone
and pulse dialling instructions.
13
Programs a delay of four seconds at any point in the phone number. Put ‘13’ in the
appropriate delay location.
14
Programs the end of the phone number.
Always review the call back phone number for accuracy before disconnecting.
Location 34
Partition, feature and report selections (five segments, FSD)
This location is used to enable certain features that can be accessed or are visible to the
user from the keypad. In addition, certain communicator reports are enabled in this
location. See
Location 122
to
Location 125
on page 79 for more information.
This location contains five segments. See the Glossary for more information.
Segment 1
1
On: enables quick arm.
2
On: enables re-exit.
3
On: enables automatic bypass.
4
On: enables silent keypad panic. This overrides audible keypad
panic (7 + 9 double press).
See
Appendix 1
for more information.
5
On: enables audible keypad panic, for example, sirens are
activated.
6
On: enables keypad aux. 1 (1 + 3 double press).
7
On: enables keypad aux. 2 (4 + 6 double press).
8
On: enables keypad multiple code attempt tamper. If enabled,
the keypad logs a tamper and stops working after six incorrect
code entries in a row.
Segment 2
1
On: enables LED extinguish. All LEDs, except the Power LED,
turn off after 60 seconds of inactivity. They turn on again with a
key stroke.
2
On: enables require code for bypassing.
3
On: enables zone bypassed sounder alert.
4
On: enables mains power/low battery sounder alert.
5
On: enables bypass toggle.
6
On: enables silent auto arm.