MP7G3BL Quick Start Manual  

 

Default Master Code 

Default Master Code is 0000. User should program Personal Master Code before use the 
system. 

Reset Master Code 

1.  Disconnect power supply. 
2.  Displace the DAP jumper from OFF to ON position. 
3.  Reconnect power supply (buzzer is activated). 
4.  Put the DAP jumper back to OFF position (buzzer is de-activated). 
5.  Keypad is in programming mode. 
6.  Press 0 follow by 4 digits Master Code and # to set new Master Code. 

Single User Mode or Multi-User Mode 

Controller consist 2 programming mode which is Single User Mode or Multi-User mode.  

Single User mode is for simple use, which only 1 user code can use to operate the output relay. 
The user code is fixed to 4 digits. This mode is always set to Auto Entry Mode in default. The 
user only need to enter 4 digits user code and does not require pressing # key. The relay will 
activate. 

Multi-User mode allows 100 user codes to operate output relay. The user code can be 4 to 8 
digits. This mode is always set to Manual Entry Mode in default. The user code followed by # 
key is required. 

Once the keypad is programmed in Auto Entry Mode, the Master code and User Codes must be 
set in the same digit length, and not need to be followed by # key. 

 

www.microidee.com

 

V1.0.0 020310

 

 

Programming Option 

1.  Use default Master Code to Entry in Programming Mode 

0000  * 
 

2.  Set System to Single User Mode or Multi User Mode & Refresh the System 

8900  # 

Set system to Single User Mode & clear all the data previously stored 

8901  # 

Set system to Multi User Mode & clear all the data previously stored 

 

3.  Install Master Code and User Code 

 

a)  Single User Mode 

0  4 digits 

Set Master Code 

1  4 digits 

1 set of User Code 

 

b)  Multi-User Mode 

0   

 

4 digits  

Set Master Code 

1  00 to 99 

4 digits  

100 set of User Code 

** Repeat step above to add next user PIN. 

 

4.  Configure Output Modes 

40 

1 to 999 

Set Lock release time from 1 to 999 seconds 

41 

 

 

Set Lock in Start / Stop Mode (toggle) 

 

 

5.  Personal Safety 

70 

 

 

After 10 successive false code, keypad lock for 30 seconds 

72 

5 to 10  

Selectable of after 5 to 10 successive false code, keypad 

 

 

 

 

Lock for 15 minutes 

76 

00 

 

Off Personal Safety function 

 
** The keypad can be reset during keypad lock by enter Master Code  #. 
 

6.  User Code Entry Mode (Auto or Manual) 

82 

Auto Entry Mode is selected. # key follows the user code is NOT  
required. The User codes must be same digit with Master Code 
and the code length can be 4-8 digits 

82 

Manual Entry Mode is selected. # key follows the user code is  
required. The user codes can be 4-8 digits and not required to be 
in the same length as Master Code 

** In Single User Mode, no matter the selection is Auto or Manual mode, the Master 
Code and User Code MUST be set to 4 digits. 

7.  Delete User Code (Multi-User Mode) 

00 to 99 

Delete particular User Code 

 

8.  Exit Programming Mode 

Exit programming mode and return to normal operation  

 