background image

secure open

Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22

www.conlan.eu • [email protected]

Code & Proximity

CP1000

Mykey - Art. No: 480015 (black), 480016 (white)

Classic - Art. No.: 482015 (black), 482016 (white)

User manual

CP1000_usermanual_ENGjan17

Summary of Contents for Classic CP1000

Page 1: ...vej 2A DK 9000 Aalborg Tel 45 72 40 60 03 Fax 45 96 32 00 22 www conlan eu info conlan eu Code Proximity CP1000 Mykey Art No 480015 black 480016 white Classic Art No 482015 black 482016 white User man...

Page 2: ...ng 4 Configuration of CP1000 4 1 Service code 4 2 Configuration overview 4 3 Change Master code 4 4 Change Service code 4 5 LED indications 4 6 Outputs 4 7 Special settings 5 One time day code 6 Block...

Page 3: ...irectly by Master code and Service code 2 Installation Mount the reader on a even surface use the following drill template for precise fit ting Connect the wires to power supply door strike assembly b...

Page 4: ...Activates output 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indication...

Page 5: ...from Key in the user position or press to leave the programming mode Changing proximity tags It s the same procedure as programming new users just overwrite the user position Delete a specific proximi...

Page 6: ...tch on only Ie the code proximity tag is permanently unlocked when the code proximity tag is en tered Programming the same user 4 times By programming the same code proximity tag on the same position...

Page 7: ...000 goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master...

Page 8: ...normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press g...

Page 9: ...or seconds is the value automatically 0 which corresponds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positio...

Page 10: ...and proximity tags only activates out put 1 High Security High Security increases the CP1000 s security by ensuring 2 positions have to be acti vated before the output is activated the positions must...

Page 11: ...ft and a series of one time codes shown in the table below Both these can be exported to a file if re quired When the information is specified the CP1000 can be set Setting the time Activation of One...

Page 12: ...uzzer sounds Turn the voltage off and disconnect the yellow and brown core The CP1000 is now reset to factory default and the user codes tags are deleted 8 Technical specifications Voltage By 12 VDC 3...

Page 13: ...D 0V active CT 2000 Prox ALARM SYSTEM A S Prox 1 3 5 7 9 2 4 6 8 0 0V GND Doorstrike 12V DC 12V DC 0V GND Doorstrike 12V DC 12V DC 12V DC 0V DC REX 0V active Hight Security external buzzer 0V active R...

Page 14: ...72 5 39 73 6 40 7 7 41 75 8 42 76 9 43 77 10 44 78 11 45 79 12 46 80 13 47 81 14 48 82 15 49 83 16 50 84 17 51 85 18 52 86 19 53 87 20 54 88 21 55 89 22 56 90 23 57 91 24 58 92 25 59 93 26 60 94 27 61...

Page 15: ...109 142 175 110 143 176 111 144 177 112 145 178 113 146 179 114 147 180 115 148 181 116 149 182 117 150 183 118 151 184 119 152 185 120 153 186 121 154 187 122 155 188 123 156 189 124 157 190 125 158...

Page 16: ...n Conlan ApS Speditorvej 2A DK 9000 Aalborg Tel 45 72 40 60 03 Fax 45 96 32 00 22 www conlan eu info conlan eu Thank you for choosing Conlan s products For further assistance please contact Our suppor...

Reviews: