background image

www.microidee.com

 

V1.0.0 020310

 

 

System Default Values 

401 

Lock release time set to 1 second 

70 

After 10 successive false codes, the keypad lock for 30 seconds 

821 

Auto Entry Mode for Single User Mode 

820 

Manual Entry Mode for Multi-User Mode 

 
 
Important Notes 

1.  After changed from Single User Mode to Multi-user Mode; or vice versa. System will takes 

approximate 2 to 3 seconds to refresh. DON NOT enter any code during the system is being 
refreshed until the 2 confirmation beeps are heard. When this is done, the keypad will reset 
to default values and all the programming data will be cleared except Master Code. 

2.  Make sure the Master Code and User Code are in length of 4 digits if the system is in Single 

User Mode. 

3.  Is it necessary to change Master Code in the length of 4 digits first before refreshing it from 

Multi-user Mode to Single User Mode. 
 

Specification 

Operation Voltage:  
12-24 Vdc 

Operation Mode:  
a)  Single User Mode with 1 set of User Code 
b)  Multi-User Mode with 100 set of User Codes 
 
Egress Input: 
Normally open referring to (-) ground. 
 
Relay Output: 
Normally Closed and Normally Open Dry Contact 
 
Dimension: 
117(H) x 74(W) x 48(D) mm 
 
Weight: 
160g net 
 
** Specifications are subject to change for modification without notice. 
 
 
 
 
 
 
 

 

 

 

www.microidee.com

 

V1.0.0 020310

 

 

MP7G3BL Worong Diagram 

 

 

Notes: 

  Connect the IN4004 as close as possible to the lock in parallel with the lock power 

terminal to absorb the back EMF to prevent it from demaging the keypad. 

  To avoid Electric-Static-Discharge from interfering with the operation of the keypad, 

always ground the (-) terminal of the keypad to earth. 

Reviews: