System Default Values
401
Lock release time set to 1 second
70
After 10 successive false codes, the keypad lock for 30 seconds
821
Auto Entry Mode for Single User Mode
820
Manual Entry Mode for Multi-User Mode
Important Notes
1. After changed from Single User Mode to Multi-user Mode; or vice versa. System will takes
approximate 2 to 3 seconds to refresh. DON NOT enter any code during the system is being
refreshed until the 2 confirmation beeps are heard. When this is done, the keypad will reset
to default values and all the programming data will be cleared except Master Code.
2. Make sure the Master Code and User Code are in length of 4 digits if the system is in Single
User Mode.
3. Is it necessary to change Master Code in the length of 4 digits first before refreshing it from
Multi-user Mode to Single User Mode.
Specification
Operation Voltage:
12-24 Vdc
Operation Mode:
a) Single User Mode with 1 set of User Code
b) Multi-User Mode with 100 set of User Codes
Egress Input:
Normally open referring to (-) ground.
Relay Output:
Normally Closed and Normally Open Dry Contact
Dimension:
117(H) x 74(W) x 48(D) mm
Weight:
160g net
** Specifications are subject to change for modification without notice.
www.microidee.com
4
V1.0.0 020310
MP7G3BL Worong Diagram
Notes:
•
Connect the IN4004 as close as possible to the lock in parallel with the lock power
terminal to absorb the back EMF to prevent it from demaging the keypad.
•
To avoid Electric-Static-Discharge from interfering with the operation of the keypad,
always ground the (-) terminal of the keypad to earth.