Introduction 2
Specifications 3
Mounting 3

Type I Mounting 3
Type II Mounting 4

BACview

2

Wiring 4

Protection 5

Summary of Contents for BACview2

Page 1: ...o SuperVision Eikon and Alert are registered trademarks of Automated Logic Corporation InterOp is a trademark of Automated Logic Corporation BACnet is a registered trademark of ASHRAE All other brand and product names are trademarked by their respective companies Technical Instructions BACview2 Hardware Guide Introduction 2 Specifications 3 Mounting 3 Type I Mounting 3 Type II Mounting 4 BACview2 ...

Page 2: ...ng you to view and change parameters locally without a separate computer However the BACview2 was not designed to serve as a job start up tool It is meant to help you operate your control system by allowing local access to the most commonly changed parameters Note that any parameter changes issued from the BACview2 exist only in the module until you transfer them to the workstation The BACview2 ca...

Page 3: ...discharge model protection to the encloser Listed By PAZX UL 916 cUL C22 2 No 205 M1983 Mounting The BACview2 rear mounting plate see Figure 2 has four mounting holes and one opening for the 14 conductor ribbon cable The rear mounting plate can be removed by releasing the four screws on the sides and is used as a template for mounting There are typically two different types of mounting Types I and...

Page 4: ...2 on page 3 Be sure not to bend or pinch the ribbon cable beneath the rear mounting plate 7 Connect the ribbon cable to the face of the BACview2 8 Reattach the BACview2 to the rear mounting plate 9 Connect the ribbon cable to the module s Auxiliary Device port mounted inside the panel box see Figure 4 on page 5 BACview2 Wiring CAUTION The BACview2 is a Class 2 device less than 30 VAC 100VA max Tak...

Page 5: ...x p ans ion A B A B A B A B A B A B A B A B IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 IN 24 IN 23 IN 22 IN 21 IN 20 IN 19 IN 18 IN 17 B A B A B A B A B A B A B A B A IN 32 IN 31 IN 30 IN 29 IN 28 IN 27 IN 26 IN 25 B A B A B A B A B A B A B A B A 0 2 0 m A 0 5 V d c T h e r m i s to r d r y c o n t a c t O n O f f G n d 2 4 V a c C la s s 2 2 4 V a c 5 0...