146
CS175-275-575-875 Installation Guide
Report
Contact ID
SIA
Zone bypass (zone
number)
570 *B
Bypass restore (zone
number)
570 *U
Near Alarm (A/B Alarm)
138 BM
Early open/late close
451 OK
Partial close
456 CF
Zone activity fault
391 NA
Report
Contact ID
SIA
Zone activity restore
391 NS
Fail to close
454 CI
RF jamming
344 XQ
RF jamming restore
344
XH
Smoke detector clean me
393
YX
Smoke detector clean me
restore
393
YZ
"
The number in parentheses following the event is the number that is reported as the zone
number. If there are no parentheses, the zone is 0. See Appendix 2 for a list of device
numbers.
* The character transmitted in this slot is the first character from the event code of the
zone that is bypassed or in trouble. See Location 127 to Location 206, starting on page
80, for more information.