background image

ACT 10 Digital Keypad

Operating & Installation Instructions

18-00001

Summary of Contents for ACT 10

Page 1: ...ACT 10 Digital Keypad Operating Installation Instructions 18 00001 ...

Page 2: ...ys ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire ACT 10 Digital Keypad Operating Installation Instructions 2 ACT 10 Digital Keypad ACT 10 ACT 10 Flush Kit ACT 10 FK ACT 10 Weather Shield ACT 10 WS Ordering Information Product Specification Number of Users 10 PIN Codes Supply Voltage 12 24 Volts AC or DC Current Co...

Page 3: ...ady for normal use Note The ACT 10 Digital Keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the button three times For Door 2 Operation 1 Enter Programming Mode 2 Change User 2 Code On the digital keypad Press Button 0 then Press Button 2 for User 2 Input the new User 2 code 4 digits 3 Assign User 2 to Door 2 On the digital keypad Pr...

Page 4: ... 3 0 7 Output function code 7 User 7 0 Door Toggle Exit programming Step Keypad Entry Operation 1 2 Set Timers 2 0 4 Timer number Buzzer sounds indicating timing wait required period 3 Stop timing Buzzer stops timer set Setting Timers Enter Programming Mode then Press 0 Relay time 5s 1 Door 2 Output 2 time 5s 2 Output 3 time 5s 3 Door Ajar time 30s 4 Guest Buzzer time 2s Timer Number Function Defa...

Page 5: ... programmed for the first code to be entered 40 Door Forced Off When set the buzzer output is activated if the door contact opens when a valid Alarm code has not been entered The output is deactivated when a valid code is next entered This is useful for monitoring fire doors etc 41 Group Disable Off When set the top five user codes 5 9 are inactive any time the interlock input is activated This re...

Page 6: ...CT10 Rev3 0 N C N O C V 0V Door Release Button for Door 2 RELAY DOOR 2 OMRON 5A 250V AC 5A 30V DC Door 2 12 24V ACDC Power Supply Shows connection for normally energised lock e g magnetic lock Shows connection for normally DE ENERGISED lock e g door strike Break Glass Unit optional Power up without link if Programming Code has been lost Shows connection for normally ENERGISED lock e g magnetic loc...

Page 7: ...ill block the air vents and trap any water which may enter the keypad If a weather shield is fitted the same applies Figure 2 ACT10 Digital Keypad_Guide to outdoor installation in exposed areas Figure 1 ACT10 Digital Keypad Schematic PSU EXIT 220 240 Volts AC Tamper 3 Inputs 100mA 3 Outputs 100mA 12 24 Volts AC DC ACT 10 Digital Keypad Operating Installation Instructions 7 Figure 2 ACT 10 Digital ...

Page 8: ...ired connections Replace the wired connectors in their correct positions and install the front housing of the ACT 10 on its back plate Any excess cable can be shoved back into the void between the cradle and the back box Secure the ACT 10 to its back plate with the security screw Fit the cradle into the back box Fit the front plate to the back box with the 4 security screws provided Unit C1 South ...

Reviews: