background image

20-Zone & 48-Zone LED Keypads V1.3

 

Installer’s Guide

Summary of Contents for Digiplex DGP-620

Page 1: ...20 Zone 48 Zone LED Keypads V1 3 Installer s Guide...

Page 2: ......

Page 3: ...M 6 Finding an Unlabeled Keypad s Serial Number 6 PROGRAMMING 7 Enter Module Programming Mode 7 Programming Methods 8 Feature Select Programming 8 Decimal Programming 9 Level Programming 9 WinLoad Pro...

Page 4: ...on Zone Closure 14 Beep on Trouble 15 Keypad Tamper Enable 16 Access Control 16 PGM PROGRAMMING 17 PGM State 17 PGM Activation Event 17 PGM Deactivation Event 18 PGM Timed Mode 19 PGM Timer 19 PGM Ba...

Page 5: ...LEDs provide the system s status at a glance Since all programming is accomplished through the keypad please read this manual carefully 1 1 SPECIFICATIONS Power input 9 16 Vdc 45mA typical Operation...

Page 6: ...n in Figure 2 1 Refer to the Digiplex Control Panel s Reference Installation Manual for the maximum allowable installation distance from the control panel 2 2 CONNECTING KEYPAD ZONES Each keypad has o...

Page 7: ...control panel and the zone s parameters must be defined The control panel does not recognize tampers originating from the keypad zone For more information on zone assignment please refer to the Digip...

Page 8: ...he PGM can provide 50mA to any device connected to it If the current drawn is to exceed the current limit a relay should be connected to the PGM as shown in Figure 2 1 2 4 FINDING AN UNLABELED KEYPAD...

Page 9: ...MODE The keypad like all other modules in the Digiplex system is programmed through the control panel To do so enter the Module Programming Mode Step 1 From Normal Mode press and hold the 0 key The ke...

Page 10: ...ad Every time the CLEAR button is pressed it will revert to the preceding step unless entering data in which case it will erase the current data entry Please note that the serial number is located on...

Page 11: ...th the WinLoad Security System Management Software the Digiplex control panels and keypads can be programmed remotely through a modem at 300 baud or on site at 19 200 baud with a 306 Adapter For more...

Page 12: ...tep 5 Enter the SERIAL of the destination keypads The destination is the keypad s you want to program with the source s data If you want to program more than one keypad with the source s data enter th...

Page 13: ...Digiplex LED Keypads 11 4 0 SYSTEM OPTIONS 4 1 BASIC OVERVIEW...

Page 14: ...FO OR R 20 Z 20 ZO ON NE E K KE EY YP PA AD DS S O ON NL LY Y The 20 Zone Keypad can be programmed to only display a certain sequence of zones in a Partitioned System Use Level Programming see sectio...

Page 15: ...Normal Mode will appear and all applicable LEDs will illuminate The AC Light if power is present The Numerical Symbols representing any open zones The Area Symbols if any areas are armed The MEM Symb...

Page 16: ...y second during the Exit Delay Timer During the final 10 seconds it will beep more rapidly to provide a final warning before the partition is armed Option 2 OFF Exit Delay beep disabled Option 2 ON Ex...

Page 17: ...Trouble Display or if the trouble is resolved see Digiplex Control Panel s Reference Installation Manual for details concerning Trouble Display The intermittent beep will re initialize whenever the t...

Page 18: ...nition options in the Digiplex Control Panel Reference and Installation manual Option 5 OFF Keypad s Tamper is disabled default Option 5 ON Keypad s Tamper is enabled 4 10 ACCESS CONTROL The Access Co...

Page 19: ...n Event occurs see section 5 2 of this manual the PGM will switch to its opposite state i e open to closed or closed to open The PGM can provide 50mA to any device connected to it Option 5 OFF PGM is...

Page 20: ...ing to enable disable options 1 to 8 Select up to eight specific events as detailed in the PGM Programming Table These buttons represent the hexadecimal values from A to F 5 3 PGM DEACTIVATION EVENT S...

Page 21: ...section 5 5 of this manual instead of the PGM Deactivation Event Option 2 OFF Deactivation as per PGM Deactivation Event default Option 2 ON PGM will deactivate according to the PGM Timer 5 5 PGM TIM...

Page 22: ...me is 1 second default Option 3 ON PGM Base Time is 1 minute 5 7 PGM OVERRIDE Section 005 Option 4 When PGM Override is enabled the keypad s on board PGM will ignore PGM Activation Events PGM Deactiva...

Page 23: ...products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expre...